Bosch Appliances EX14 Troubleshooting, Problem, Possible, Likely Solution, Cause

Models: EX14

1 44
Download 44 pages 43.58 Kb
Page 39
Image 39
7Troubleshooting

EX14 Marine Camera

Troubleshooting en 39

 

 

7Troubleshooting

PROBLEM

POSSIBLE

LIKELY SOLUTION

 

CAUSE

 

 

 

 

No Video

Power supply

Check input power connections at

 

connections

the cable leads. Check for loose

 

 

wires

 

 

 

No Video

Power supply -

If connected to DC check input

 

Voltage range

voltage range of 12–24V. If

 

 

connected to AC , check input

 

 

voltage range of 12–24V. Measure

 

 

the voltage and current at the Input

 

 

power cable. The current should be

 

 

>.02 A and <1.0 A.

 

 

 

No video

Video

Determine if wiring polarity at

 

connections

Video Connector terminal block is

 

 

correct. Check the cable and BNC

 

 

connector. If still no video, connect

 

 

the camera directly to the monitor.

 

 

Check the video signal . If okay, the

 

 

problem is with the

 

 

interconnections. If still no video,

 

 

contact your Bosch service center.

 

 

 

Poor picture -

Poor video signal

Ensure the video cable is correctly

Snowy image

 

matched and terminated with

 

 

75 ohms at each end. Make sure

 

 

the video cables are similar types.

 

 

 

Snowy Image

Noisy power

Check connections. Relocate or

 

supply

replace the power supply.

 

 

 

Horizontal scan

Ground looping

Check the coax cable shield is not

lines, rolling up or

on video cable

touching ground, e.g.a t couplings.

down

 

Check video polarity.

 

 

 

Negative,

Low voltage

Check voltage at the input power

scrambled or

 

cable. Must be >12 VDC or

faded image

 

>12 VAC.

 

 

 

Bosch Security Systems, Inc.

Instruction Manual

F.01U.240.878 1.0 2011.07

Page 39
Image 39
Bosch Appliances EX14 instruction manual Troubleshooting, Problem, Possible, Likely Solution, Cause