AutoDome EasyConnections 7
5.2 | Connecting the Video |
Coaxial cable terminated with BNC connectors is the most common method for transmitting composite video. To connect the video, do the following:
1.Terminate the coaxial cable from the head end system with a male BNC connector.
2.Connect the head end video cable to the yellow Video Out connector from the base of the camera.
5.3 |
| Connecting the Power | |
|
| To connect the power, do the following: | |
|
|
| |
| ! | WARNING! This unit accepts 24 VAC or 12 V DC, 1 A power only. Do not connect 120 V or | |
| 230 V to this camera. | ||
|
|
| |
|
|
|
|
|
| 1. | Locate the cable assembly with a two (2) pin mating connector on one end and the |
|
|
| orange and red flying leads on the other end. |
|
| 2. | Connect one lead of the 12 V DC or 24 VAC power source to the red wire. |
|
| 3. | Connect one lead of the 12 V DC or 24 VAC power source to the orange wire. |
|
|
| |
| i | NOTICE! Use certified / Listed Class 2 power supply transformer only. | |
|
|
|
5.4 Connecting the Alarm Input
i
The AutoDome Easy provides one (1) alarm input. This alarm input can be activated by dry contact devices, which triggers the dome camera to move to a
Section 10: Program and Operation for configuring alarm input. To connect the alarm input, do the following:
1.Locate the cable assembly with a two (2) pin blue mating connector on one end and the blue and violet flying leads on the other end.
2.Connect the ground of the alarm source dry contact to the blue wire (alarm common).
3.Connect the alarm out of the alarm source dry contact to the violet wire (alarm input).
| Alarm Common Blue Wire | |
| ALARM INPUTS 1 TO 7 | |
|
| |
Dry |
| |
DRY | DOME CONNECTOR | |
CONTACTContact | ||
| ||
|
|
AlarmGROUNDInput Violet Wire
Fig. 5.3 N.O. - Normally Open Non-supervised Connections
NOTICE! All the connectors marked GND are common.
Bosch Security Systems, Inc. | Installation and Configuration Manual | December 06, 2006 F01U032279 |