30 en Test SoftwareGlobal View Station 1000

6.2.1

Reset Button

 

SW1 – resets the board to default settings

 

Resetting should be used when changing the system address or communication protocol

 

 

when the unit is powered

6.2.2

Address Selection

 

– DIP1 – Switches 1-4

 

– Switches in various combinations of on/off will allow address setting of 1-16

 

– Default address: 1

 

– Address MUST be the same for Auxiliary Control board (in PSU), Camera Control board

 

(in camera assembly), and Code Translator (in PSU)

 

– See the GVS1000 Installation Manual for further details

6.2.3

Protocol Selection

 

– For Biphase models, ensure Pelco D mode is enabled.

 

– DIP1 – Switch 5

 

– Switch ON: Pelco D mode

 

– Switch OFF: Pelco P mode

 

– Default: Pelco D mode (switch off)

 

– Switch UP position is ON

6.2.4

System Communication

 

– T1 – Connects to system input

 

– to receive system communication from controller

 

– required for both simplex (2-wire configuration) and duplex (4-wire configuration)

 

– T2 – connects to system output

 

– to send system communication to controller – OPTIONAL

 

– required only for duplex (4-wire configuration)

 

– LED10 – indicates communication traffic to the system (LED always on when diagnostics

 

function engaged)

6.2.5

Self Test Diagnostic Function

 

– DIP1 – Switch 6

 

– Switch ON and jumper JP8 ON: diagnostics function on

 

– Switch OFF and jumper JP8 OFF: diagnostics function off

 

– Default: diagnostics function off (switch off, jumper JP8 OFF)

 

– Tests Aux1 through 8 sequentially, and then tests motor Pan LEFT/RIGHT and Tilt UP/

 

DOWN respectively

 

– 3 seconds for each test function

 

– Stops only at end of cycle

6.2.6

Termination Jumpers

 

JP6 / JP7 – controls the impedance communication lines

 

 

JP6 – T1 telemetry jumper

 

 

JP7 – T2 telemetry jumper – ALWAYS OPEN

 

JP8 – diagnostics tool jumper

6.2.7

Photocell Control Adjustments

 

– CN7 – connection to photocell

 

– VR1 – sensitivity adjustment for photocell switching

 

CCW rotation decreases lux switch point

 

CW rotation increases lux switch point

F.01U.173.867 2.0 2010.11