30 en Test SoftwareGlobal View Station 1000
6.2.1 | Reset Button | |
| – | SW1 – resets the board to default settings |
| – | Resetting should be used when changing the system address or communication protocol |
|
| when the unit is powered |
6.2.2 | Address Selection |
| – DIP1 – Switches |
| – Switches in various combinations of on/off will allow address setting of |
| – Default address: 1 |
| – Address MUST be the same for Auxiliary Control board (in PSU), Camera Control board |
| (in camera assembly), and Code Translator (in PSU) |
| – See the GVS1000 Installation Manual for further details |
6.2.3 | Protocol Selection |
| – For Biphase models, ensure Pelco D mode is enabled. |
| – DIP1 – Switch 5 |
| – Switch ON: Pelco D mode |
| – Switch OFF: Pelco P mode |
| – Default: Pelco D mode (switch off) |
| – Switch UP position is ON |
6.2.4 | System Communication |
| – T1 – Connects to system input |
| – to receive system communication from controller |
| – required for both simplex |
| – T2 – connects to system output |
| – to send system communication to controller – OPTIONAL |
| – required only for duplex |
| – LED10 – indicates communication traffic to the system (LED always on when diagnostics |
| function engaged) |
6.2.5 | Self Test Diagnostic Function |
| – DIP1 – Switch 6 |
| – Switch ON and jumper JP8 ON: diagnostics function on |
| – Switch OFF and jumper JP8 OFF: diagnostics function off |
| – Default: diagnostics function off (switch off, jumper JP8 OFF) |
| – Tests Aux1 through 8 sequentially, and then tests motor Pan LEFT/RIGHT and Tilt UP/ |
| DOWN respectively |
| – 3 seconds for each test function |
| – Stops only at end of cycle |
6.2.6 | Termination Jumpers | ||
| – | JP6 / JP7 – controls the impedance communication lines | |
|
| – | JP6 – T1 telemetry jumper |
|
| – | JP7 – T2 telemetry jumper – ALWAYS OPEN |
| – | JP8 – diagnostics tool jumper |
6.2.7 | Photocell Control Adjustments | |
| – CN7 – connection to photocell | |
| – VR1 – sensitivity adjustment for photocell switching | |
| – | CCW rotation decreases lux switch point |
| – | CW rotation increases lux switch point |