Image 17
Table 8 Restrictors table

Installation instructions

Use table below to define which restrictor to be used.

 

 

Total equivalent length (ft)

Restrictor Ø

 

 

 

 

GWH345

NG

20 - 38

38

 

 

38 - 78

40

 

 

 

 

 

 

 

 

 

 

 

 

18 - 28

44

NG

 

 

28 - 40

47

GWH450

 

 

40 - 65

50

 

 

 

 

65 - 78

55

 

 

 

 

 

 

Total equivalent length (ft)

Restrictor Ø

 

 

 

 

GWH345

LPG

20 - 38

38

 

 

38 - 78

40

 

 

 

 

 

 

 

 

LPG

18 - 28

47

 

 

GWH450

28 - 50

50

 

 

50 - 78

55

 

 

 

 

Table 8 Restrictors table

After installation is complete, check CO2 levels per chapter 3.9.

Combustion air inlet connection

The combustion air inlet accessory can only be connected to the top right of the appliance. The left side must remain sealed.

Note: Before installing the combustion air inlet accessory, the appropriate inlet air restrictor must be determined using Tables 6, 7 and 8.

Refer to Fig. 15 for mounting sequence.

BPlace gasket, deflector, gasket and inlet air restrictor on the air inlet opening lining up screw holes as seen in Fig. 15.

Fig. 15 Mounting sequence

aGasket

bDeflector

cRestrictor

dAdaptor

BAttach the combustion air inlet accessory (8 705 504 141) to the top of the unit (position 3) using the 4 screws provided.

BInstall 3" combustion air pipe over the air inlet accessory. If using flexible piping, secure with a clamp (position 4, not included).

Fig. 16 Exhaust air inlet accessory

6 720 607 909

17

Page 17
Image 17
Bosch Appliances GWH-345/450-ESR-N manual Restrictors table, Combustion air inlet connection, Mounting sequence