Appliance details
2.6Applications
Caution: the water heater which will be used to supply potable water shall not be connected to any heating system or component(s) previously used with a nonpotable water heating appliance.
Introduction
The application designs provided in this manual are general guides to be used when installing this recirculating water heater.
Pump Sizing
Required PS pumps are Taco 007 Bronze or Grundfos
Caution: Do not overpump the heater. Maximum 5 gpm water flow permitted through the heater.
Instantaneous water heater (direct tank load design)
Note: maximum amp draw: 1,5A. Do not connect additional pump to the appliance but use a relay panel if powering multiple pumps.
Fig. 6
Front cover
Low voltage access cover
Control panel
Fig. 7 Service position to access water and electric connections
8 | 6 720 607 909 |