Plena Message Manager Installation and Operating Manual Operation
en 19
The status bar at the bottom of the screen contains three fields:
-The STATUS field shows the progress of the uploading process.
-The RS232 PORT shows the RS232 data during uploading.
-The rightmost box of the status bar shows the actual upload time.
On the supplied
With the help of this program the sample rate of the .wav files can be changed, if required. It is recommended to use the lowest sample rate that does not degrade the audio quality.
Proceed as follows:
•Start the program r8brain.exe.
•Browse to the .wav file that must be modified.
•Browse to the folder in which the modified file must be placed.
•If required, change the message file name in the Browse menu.
•Enter the output sample rate in the appropriate field or click on the output sample rate in the
•Select
•Click on Perform r8brain. A progress bar shows the progress of the conversion.
•To convert from stereo .wav files to mono use the program Sound Recorder that comes with Windows®. Generally, you can find this program via Start > Programs > Accessories > Entertainment > Sound Recorder.
4.2 Play-back messages
When an announcement is started via a trigger contact, the corresponding trigger indicator LED (8) will light up.
Within an announcement there is no possibility for repetition loops of individual messages. However the same message may be programmed in the sequence more than once (max. 4).
Trigger inputs have serial priority, i.e. input 1 has priority over trigger input 2, 2 over 3, etc.
When an announcement is overridden with an announcement with a higher priority, the first indicator LED will extinguish and the new LED will light up. Lower priority triggers will be ignored.
The LED of the running message is flashing (2 Hz). If the current announcement is interrupted via RS232 by a higher priority call from the connected system
The front panel of the unit contains six pushbuttons (9) to activate announcements 7 to 12, effectively in parallel with the trigger inputs 7 to 12.
If the unit is connected to the LBB1925 via RS232, trigger inputs 1 through 6 will be processed with a priority equal to the
This priority level affects only the priority of the announcements compared to other sources connected to the system
If a repeating announcement is interrupted by a higher priority call via the system