Bosch Appliances LBB 1965 manual Controls, Environmental conditions, General, Trigger inputs Screw

Models: LBB 1965

1 26
Download 26 pages 24.95 Kb
Page 23
Image 23
5.5 Controls

Plena Message Manager Installation and Operating Manual Technical data

en 23

5.5 Controls

Trigger inputs (Screw)

 

Activation

contact closure

Supervision

on trigger inputs 1-6, selectable

Supervision method

loop resistance check

Control outputs (Screw)

 

Message active relay

100 V, 2 A (voltage free, SPDT)

Fault relay

100 V, 2 A (voltage free, SPDT)

RS232 (9-pin D-sub)

 

PC to LBB1965/00

115 kb/s, N, 8, 1, 0 (upload)

LBB1965/00 to LBB1925/10

19.2 kb/s, N, 8, 1, 0 (zone control)

5.6 Environmental conditions

Operating temperature range

-10 to +55 °C

Storage temperature range

-40 to +70 °C

Relative humidity

< 95%

5.7 General

EMC emission

acc. to EN 55103-1

EMC immunity

acc. to EN 55103-2

Dimensions

56 x 430 x 270 mm (19wide, 1U high, with feet)

Weight

approx. 3 kg

19mounting brackets

included

Bosch Security Systems 2003-09 9922 141 50502en