Plena Message Manager Installation and Operating Manual External settings and connections

en 14

The message manager can be used with all Plena amplifiers via the Cinch output (4) or the XLR Output (6). The level of the messages can be set via the message volume control (2).

To fully benefit from the features of the message manager in the overall Plena system (e.g. to distribute pre-recorded messages to pre-programmed zones) the unit must be connected via the system pre-amplifier LBB1925. To do this, use the RS232 cable and the audio cable supplied.

There are several ways to connect the message manager to the system pre-amplifier:

- Connecting the Cinch output (4) of the message manager to the Cinch PC Audio In (R) line input of the sys- tem pre-amplifier, as shown in figure 3.2 (in which the LBB1961 functions as a BGM source).

-Connecting the XLR output (6) of the message manager to the points 1 and 3 of the 8-pole DIN socket of the system pre-amplifier.

3.3 Loopthrough audio connections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LBB1920

 

 

 

 

Dir.Out1

 

Dir.Out2

Dir.Out3

 

Dir.Out4

 

 

 

 

Ins/ Casc / Emgln

 

Ins/ Casc Out

 

 

Master Line Out

Master Mic. Out

 

 

 

115V

230V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LBB 1920/00

 

Apparatus delivired

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8900 192 00005

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115/230V~,50/60Hz

connected for 230V-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ins/Casc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-

3

 

 

 

Rated input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

power: 25VA

 

 

 

 

 

 

 

 

 

+

GND

GND

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

5

Warning

 

T0,5AL250V

 

 

1-

3

3

 

1

 

1-

2

- 1

1

-

2

 

1-

3

 

 

 

 

 

 

 

 

 

1-

3

 

 

 

 

 

This apparatus must be earthed

 

 

5

2

4

 

3

3

 

3

 

 

4

5

 

 

 

 

 

 

 

 

 

4

5

 

 

 

 

 

 

 

 

 

 

 

4

5

 

 

 

 

4

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EMG Out

DC In

DC Out

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

1/Line

 

 

 

2/Line

 

 

 

 

 

 

 

 

 

3/Line

 

 

 

 

 

 

 

 

 

4/Line

 

 

 

 

 

+24V-

+24V-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LBB1965

 

 

 

 

 

 

Loop through

 

 

Supervision

C

 

+

Msg Active

Trigger Input

 

 

 

 

 

 

 

 

 

RS232 to LBB1925

 

Apparatus delivered connected for 230V~

 

 

 

 

 

 

 

 

 

 

 

24V

NC

C

NO

1

2

3

4

5

6

7

8

9

10

11

12

 

 

 

230V~ 50/60Hz

 

 

 

 

 

 

 

 

 

 

 

NC

NO

 

 

 

 

 

 

 

LBB 1965/00￿

 

 

 

In

 

 

 

Pilottone

 

 

 

 

 

Fault

 

 

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8900 196 5005

 

 

 

 

 

 

 

Mains

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trigger Input 1-6

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WK

 

 

 

 

 

 

 

 

Out

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S/N

 

 

Rated Input

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pilot

Message

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Warning

 

Power:50VA

 

 

In

Out

 

1 2 3 4 5 6 7 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS232 to PC

 

 

 

 

To.5L250V

 

Tone

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This apparatus must be earthed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LBB1938

 

 

 

 

 

 

 

Input 1 Prior ity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input 1

Input 2

Slave Input

Loopthrough 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Priority

Enable

100V

Input 2 Program

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loopthrough 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Direct O utput

 

 

 

 

 

 

 

 

 

 

 

Input 1 Prior ity

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2..24V-Input 1

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0V-Input 2

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input 2 Enable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2..24V-Enable

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8ohm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0V-Mute

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2..24V GND

2..24V GND 100V 0

Slave Input 100V 100V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100V/70V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100V

0

70V

0

8

 

 

 

 

 

 

 

Default Off

Default On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input 1-Priority

 

Input 2-Program

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Priority O nly

 

Priority Controlled O utput

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Priority

 

Priority O nly

No Priority

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Priority

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100V

0

 

100V

0

 

 

 

 

 

 

Input

Loopthrough

Input

 

Loopthrough

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Warning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This apparatus must be earthed

 

 

Figure 3.3

It is possible to connect the LBB1965 message manager between a mixer pre-amplifier and a power amplifier. When the message manager is not active, the mixer pre-amplifier is routed to the power amplifier. However, when the message manager becomes active, this loopthrough connection is interrupted and the message manager is switched to the power amplifier.

Figure 3.3 shows this configuration example in which the Plena Mixer Pre-amplifier LBB1920 is used with a Plena Power Amplifier LBB1938. This is a high priority application, as the message manager has absolute priority.

Bosch Security Systems 2003-09 9922 141 50502en

Page 14
Image 14
Bosch Appliances LBB 1965 manual Loopthrough audio connections, LBB1920