Bosch Appliances LE10 2.3Main applications, 2.4Description of the different modes, Mode, Name

Models: LE10

1 24
Download 24 pages 15.88 Kb
Page 7
Image 7
2.3Main applications

LE10 Radio Receiver

Product information en

7

 

 

 

2.3Main applications

LE10 Radio Receiver as small stand alone call system

After receiving a radio signal from a programmed radio transmitter, the relay output switches a siren or a lamp to indicate locally a wireless call.

LE10 Radio Receiver connected to a emergency call system via relay contact

After receiving a radio signal from a programmed radio transmitter, the relay will be switched. This relay output is connected to a wired emergency call system by wire and hereby a call will be generated or forwarded.

LE10 Radio Receiver as part of a Resident Alert System monitoring dementia

After receiving a signal from a dementia transmitter, the relay will be activated to close a monitored door.

2.4Description of the different modes

Mode

Name

Description

 

 

 

1

Normal

20 wireless transmitters can be programmed.

 

 

Calls are indicated by the red LED and Relay 1.

 

 

A battery-low signal is indicated by the red

 

 

LED and Relay 2.

 

 

 

2

Normal, with red LED

The same functions as in mode 1 are available,

 

deactivated at

except for the battery-low signal which is not

 

battery-low indication

indicated by the red LED, but only by Relay 2.

 

 

 

3

Dementia

The MIYS37L and MIYS37E wireless

 

 

transmitters are detected. Relay 1 can be used

 

 

to lock a monitored door. Relay 2 can be used

 

 

to interrupt a monitoring loop.

 

 

 