DinionXF Installation Manual
EN 24
Install I/O --> Alarm submenu
Function | Selection | Description |
ACTIVE | NONE, HIGH, | Selects active_HIGH or active_LOW for the alarm |
| LOW | input connector. Select NONE to disable alarm |
|
| switching. |
|
|
|
ACTION | NONE, MONO, | Selects the operating mode of the camera upon |
| MODE1, MODE2, | switching the alarm input. |
| MODE3 |
|
ALARM | VMD, REMOTE, | • Select VMD to close the output relay upon VMD |
OUT | DAY/NIGHT, | alarms. |
| FILTER MOVE | • Select REMOTE to make the output relay available |
|
| to remote communication devices. |
|
| • Day/night: the alarm output relay closes if the |
|
| camera operates in monochrome mode. |
|
| • Filter move: the alarm output relay closes before the |
|
| filter starts moving (in either direction) and opens |
|
| when the video level has stabilized (2 - 3 seconds). |
|
|
|
EXIT |
| Return to the I/O menu |
|
|
|
Install sync submenu
Function
SYNC
DETECTED SYNC
VPHASE
HPHASE
SUB
PHASE
EXIT
Selection
INTERNAL, LINE LOCK, HV LOCK,
GENLOCK
0, 2, … 358
0, 2, … 358
Description
Select INTERNAL for free running camera operation, select LINE LOCK to lock to the power supply frequency, select HV LOCK to lock to the signal supplied to the external sync input, select GENLOCK to lock the subcarrier as well.
Shows the actual sync mode used by the camera.
Adjusts the vertical phase offset (when in LINE LOCK mode and a valid power supply frequency is detected).
Adjust the horizontal phase offset (when in EXT lock mode and a valid input signal is detected)
Adjusts the
Return to the INSTALL menu
Note
VPHASE, HPHASE and
Bosch Security Systems