Bosch Appliances LTC 0495, LTC 0620 Install sync submenu, Install I/O -- Alarm submenu, En

Models: LTC 0495 LTC 0620

1 29
Download 29 pages 25.99 Kb
Page 24
Image 24
Install I/O --> Alarm submenu

DinionXF Installation Manual

EN 24

Install I/O --> Alarm submenu

Function

Selection

Description

ACTIVE

NONE, HIGH,

Selects active_HIGH or active_LOW for the alarm

 

LOW

input connector. Select NONE to disable alarm

 

 

switching.

 

 

 

ACTION

NONE, MONO,

Selects the operating mode of the camera upon

 

MODE1, MODE2,

switching the alarm input.

 

MODE3

 

ALARM

VMD, REMOTE,

• Select VMD to close the output relay upon VMD

OUT

DAY/NIGHT,

alarms.

 

FILTER MOVE

• Select REMOTE to make the output relay available

 

 

to remote communication devices.

 

 

• Day/night: the alarm output relay closes if the

 

 

camera operates in monochrome mode.

 

 

• Filter move: the alarm output relay closes before the

 

 

filter starts moving (in either direction) and opens

 

 

when the video level has stabilized (2 - 3 seconds).

 

 

 

EXIT

 

Return to the I/O menu

 

 

 

Install sync submenu

Function

SYNC

DETECTED SYNC

VPHASE

HPHASE

SUB

PHASE

EXIT

Selection

INTERNAL, LINE LOCK, HV LOCK,

GENLOCK

0, 2, … 358

-25, …, 0, … +125

0, 2, … 358

Description

Select INTERNAL for free running camera operation, select LINE LOCK to lock to the power supply frequency, select HV LOCK to lock to the signal supplied to the external sync input, select GENLOCK to lock the subcarrier as well.

Shows the actual sync mode used by the camera.

Adjusts the vertical phase offset (when in LINE LOCK mode and a valid power supply frequency is detected).

Adjust the horizontal phase offset (when in EXT lock mode and a valid input signal is detected)

Adjusts the sub-carrier phase offset (when in EXT LOCK mode and a valid sub-carrier is detected).

Return to the INSTALL menu

Note

VPHASE, HPHASE and SUB-PHASE cannot be accessed if there is no valid locking signal.

Bosch Security Systems 2004-01 V1.0

Page 24
Image 24
Bosch Appliances LTC 0495, LTC 0620 Install sync submenu, Install I/O -- Alarm submenu, DinionXF Installation Manual, En