LTC 8540/00 Series Instruction Manual Installation | EN 10 |
|
|
Typically any 2 conductor wire can be used between the rear panel terminal block containing the unit relay outputs and the VCR alarm input. If some other external device is to be controlled, do not exceed the relay ratings of 10 W, 0.75 A.
4.7Interface Port Pinouts
Follow the table below if a cable other than the one supplied with the LTC 8540/00 will be used.
Function | |
1 | Chassis Ground |
2 | Receive |
3 | Transmit |
4 | CTS |
5 | RTS |
6 | Data Ground |
7 | Data Ground |
8 | 12 VAC in or 12 VDC in |
9 | 12 VAC in or 12 VDC in |
|
|