LTC 9385 Series Instruction Manual Installation | EN 11 |
|
|
Recommended Maximum Cable Lengths
Models | Wire Size | Distance | |||
|
| mm2 | AWG | meters | feet |
(115 VAC) | 1.5 | 16 | 1000 | 3280 | |
|
| 2.5 | 14 | 1600 | 5250 |
|
| 4 | 12 | 2500 | 8200 |
(24 VAC) | 0.5 | 22 | 10 | 30 | |
|
| 0.5 | 20 | 15 | 50 |
|
| 1 | 18 | 25 | 80 |
|
| 1.5 | 16 | 40 | 120 |
|
| 2.5 | 14 | 70 | 210 |
(230 VAC) | 1.5 | 16 | 4000 | 13000 | |
|
| 2.5 | 14 | 6400 | 21000 |
|
| 4 | 12 | 10000 | 32800 |
1.Use the
2.Allow enough cord for connection to the terminal block; approximately, 130mm (5in.). Strip no less than 6mm (0.24in.) and no more than 8mm (0.31in.) of insulation away from the wires making sure not to nick the wires.
3.A screw/terminal lug is provided for securing a safety ground. To attach the safety grounding wire of the power cord (green 115volt, green/yellow 230volt), first unscrew the terminal lug and strip and crimp the grounding wire into the lug. Next, reattach the terminal lug to the rail assembly using the M4 x 10 screw and lock washer provided. See FIGURE 8.
FIGURE 8 Securing the Ground Wire
4.Connect both the line and neutral wires of the power cord to the terminal block. Make sure the line and neutral wires are connected to the correct positions on the terminal block that are across from the appropriate colored wire. See FIGURE 9.
FIGURE 9 Attaching Line and Neutral Wires
5.Pull any excess cord through the
Securely tighten all fittings to ensure a liquid- tight seal. Not doing so could damage the camera, the housing, or both.
5.8.2Camera Power Connections
LTC 9385/60 Housings
These housings are to be connected to 115VAC, and are designed for use where site power is 115volts. The LTC 9385/60 housings should only be used with 115volt cameras. The integral heater/defogger requires 115volts. The housing is shipped with the heater/defogger connected to the terminal block.
Installing a 115 volt camera into the LTC 9385/60 housing simply requires the camera's line cord to be plugged into the NEMA