LTC 9385 Series Instruction Manual Installation

EN 11

 

 

Recommended Maximum Cable Lengths

Models

Wire Size

Distance

 

 

mm2

AWG

meters

feet

-1

(115 VAC)

1.5

16

1000

3280

 

 

2.5

14

1600

5250

 

 

4

12

2500

8200

-2

(24 VAC)

0.5

22

10

30

 

 

0.5

20

15

50

 

 

1

18

25

80

 

 

1.5

16

40

120

 

 

2.5

14

70

210

-4

(230 VAC)

1.5

16

4000

13000

 

 

2.5

14

6400

21000

 

 

4

12

10000

32800

1.Use the liquid-tight fitting on the left of the housing to route the power supply cord into the housing.

2.Allow enough cord for connection to the terminal block; approximately, 130mm (5in.). Strip no less than 6mm (0.24in.) and no more than 8mm (0.31in.) of insulation away from the wires making sure not to nick the wires.

3.A screw/terminal lug is provided for securing a safety ground. To attach the safety grounding wire of the power cord (green 115volt, green/yellow 230volt), first unscrew the terminal lug and strip and crimp the grounding wire into the lug. Next, reattach the terminal lug to the rail assembly using the M4 x 10 screw and lock washer provided. See FIGURE 8.

FIGURE 8 Securing the Ground Wire

4.Connect both the line and neutral wires of the power cord to the terminal block. Make sure the line and neutral wires are connected to the correct positions on the terminal block that are across from the appropriate colored wire. See FIGURE 9.

FIGURE 9 Attaching Line and Neutral Wires

5.Pull any excess cord through the liquid-tight fitting and tighten the flex fitting to 8.5N-m to 9.0N-m (75in. lb to 80in. lb). This torque rating is approximately 1 to 1 1/2 turns past the point that the fitting starts to grip the cord. Failure to do so will result in water damage to all electronic parts. Use a tie wrap (included) to provide strain relief on the power cord at the exit point (inside the unit).

Securely tighten all fittings to ensure a liquid- tight seal. Not doing so could damage the camera, the housing, or both.

5.8.2Camera Power Connections

LTC 9385/60 Housings

These housings are to be connected to 115VAC, and are designed for use where site power is 115volts. The LTC 9385/60 housings should only be used with 115volt cameras. The integral heater/defogger requires 115volts. The housing is shipped with the heater/defogger connected to the terminal block.

Installing a 115 volt camera into the LTC 9385/60 housing simply requires the camera's line cord to be plugged into the NEMA 5-15R receptacle provided. See FIGURE 10.

Bosch Security Systems January 26, 2005

Page 11
Image 11
Bosch Appliances LTC 9385 instruction manual Recommended Maximum Cable Lengths, Camera Power Connections