LTC 9385 Series Instruction Manual Installation

EN 8

 

 

5.2Tools Required

Flat blade screwdriver

Phillips head screwdriver

M7 (7mm) hex wrench or socket

M3 (3mm) hex wrench

M4 (4mm or 5/32in.) hex wrench

M8 (8mm or 5/16in.) hex wrench

Adjustable wrench

Wire cutter/stripper/crimper tool

5.3Hardware Required

M6 screws (X3) or 1/4in. screws (X3)

M6 nuts (X3) or 1/4in. nuts (X3)

M6 lock washers (X3) or 1/4in. lock washers (X3)

5.4Cable Requirements

Video Transmission (Coaxial)

 

 

Cable Type

RG-59/U (Runs < 1000ft)

 

RG-11/U (Runs < 2000ft)

 

 

Cable Size

Outside diameter between 4.6mm

 

and 7.9mm (0.181in. and 0.312in.)

 

 

Cable Shape

Round

 

 

Shield

≥ 93% Braided Copper Shield

 

 

Center Conductor

Stranded Copper Center

 

 

DC Resistance

≥ 15Ω/1000ft (RG-59/U)

 

≥ 6Ω/1000ft (RG-11/U)

 

 

Cable Impedence

75Ω

 

 

Agency Rating

UL

 

 

Environmental

Outdoor rated

 

 

Temperature Rating

≥ 80 °C (176 °F)

 

 

Sources

Belden 9259

 

Belden 9238

 

 

 

 

Input Power Cord - North American

 

 

Cable Type

SJTOW-A Rated

 

 

Cable Size

Outside diameter between 4.3mm

 

and 11.9mm (0.170in. and 0.470in.)

 

 

Cable Shape

Round

 

 

Conductors

3 conductor version and

 

2 conductor version

 

 

Agency Rating

UL/C.S.A., UL VW-1

 

 

Environmental

Outdoor rated

 

 

Temperature Rating

105 °C

 

 

Voltage Rating

300 V

 

 

Sources

Belden 19506

 

Belden 19509

 

Northwire 573939

 

 

Input Power Cord - European

 

 

 

Cable Type

 

H05RN-F3G0.75 and

 

 

H05RN-F3G1.00

 

 

 

Cable Size

 

Outside diameter between 4.3mm

 

 

and 11.9mm (0.170in. and 0.470in.)

 

 

 

Cable Shape

 

Round

 

 

 

Conductors

 

3 conductor version and

 

 

2 conductor version

 

 

 

Agency Rating

 

VDE

 

 

 

Environmental

 

Outdoor rated

 

 

 

Sources

 

Olflex 1600252

 

 

Olflex 1600253

 

 

 

 

 

 

 

Lens Control Cable

 

 

 

Cable Type

 

Jacketed Multiconductor Cable

 

 

 

Cable Size

 

Outside diameter between 4.3mm

 

 

and 11.9mm (0.170in. and 0.470in.)

 

 

 

Cable Shape

 

Round

 

 

 

Shield

 

Overall shielding

 

 

 

Conductors

 

Stranded 20 to 16 AWG wire

 

 

 

No. of Conductors

 

4 and 8

 

 

 

Conductor Insulation

 

Color coded

 

 

 

Sources

 

Belden 9552

 

 

Belden 9554

5.5Disassembly and Mounting

1.Detach the hardware kit from the housing.

2.Use a M7 hex wrench or socket to remove the two M4 screws from the housing cover. Save all hardware, which will be needed in reassembly. See FIGURE 1.

M4 Screws

FIGURE 1 Removing the M4 Cover Screws

Bosch Security Systems January 26, 2005

Page 8
Image 8
Bosch Appliances LTC 9385 Tools Required, Hardware Required, Cable Requirements, Disassembly and Mounting