LTC 9385 Series Instruction Manual Installation | EN 12 |
|
|
LTC 9385/20 Housings
These housings are to be connected to 24VAC, and are designed for use where site power is 24volts. The LTC 9385/20 housings should only be used with 24volt cameras. The integral heater/defogger requires 24volts. The housing is shipped with the heater/ defogger connected to the terminal block.
Installing a 24 volt camera into the LTC 9385/20 housing simply requires the two flying leads be attached to the camera's terminal block. See FIGURE 10.
LTC 9385/50 Housings
These housings are to be connected to 230VAC, and are designed for use where site power is 230volts. The LTC 9385/50 housings should only be used with 230volt cameras. The integral heater/defogger requires 230volts. The housing is shipped with the heater/defogger connected to the terminal block.
Installing a 230 volt camera into the LTC 9385/50 housing simply requires the camera's line cord to be plugged into the Schuko inline receptacle provided.
See FIGURE 10.
FIGURE 10 Camera Connections
5.9Video Coax Connection
WARNING: Only use the cables specified under INSTALLATION, Cable Requirements for wiring of the video coax connection.
If lens control or
1.Install the long flexible portion of the small
2.Attach a BNC connector to the coax and connect it to the camera. Pull any excess cable through the
Be sure to securely tighten all fittings to ensure a
If no lens control or
1.Install the long flexible portion of a large
2.Attach a BNC connector to the coax and connect it to the camera. Pull any excess cable through the liquid tight fitting and tighten the flex fitting to
Be sure to securely tighten all fittings to ensure a