Caregiver Departure

MIYN46 Wall TransmitterUse en 19

 

Insertion of the coded key is signaled by green flashes on the signal lamp and by activating the

 

Staff Presence relay.

5.7

Caregiver Departure

 

The Caregiver Departure message is triggered when the Caregiver removes the coded key

 

from the housing, when leaving the room.

 

The Caregiver Departure message is not repeated.

 

Removing the coded key is signaled by switching off the green flashes on the signal lamp and

 

by releasing the Staff Presence relay.

5.8

Daily Message and Battery Low Message

 

The radio transmission can be checked by way of the daily message which is automatically

 

sent about every 24 hours. When the battery voltage is too low, the daily message is replaced

 

by a Battery Low message. The duration of the daily message is 1.7 seconds.

 

The transmission of the Daily Message can be disabled by setting the solder bridge B5 (this

 

does not influence the transmission of the Battery Low message).

5.9

Error Message

 

The Error Message is sent one time if the device has detected a general dysfunction, or if one

 

of the following triggering devices remains in its activated position for up to 4 minutes:

 

Call for Help

 

Acknowledgement button

 

Call for Assistance

 

Reserve Call

 

 

 

i

NOTICE!

 

The device connected to the Technical Alarm input is allowed to remain in the activated posi-

tion; without transmission of the Error Message.

 

 

 