MIYN46 Wall TransmitterUse en 19
| Insertion of the coded key is signaled by green flashes on the signal lamp and by activating the | |
| Staff Presence relay. | |
5.7 | Caregiver Departure | |
| The Caregiver Departure message is triggered when the Caregiver removes the coded key | |
| from the housing, when leaving the room. | |
| The Caregiver Departure message is not repeated. | |
| Removing the coded key is signaled by switching off the green flashes on the signal lamp and | |
| by releasing the Staff Presence relay. | |
5.8 | Daily Message and Battery Low Message | |
| The radio transmission can be checked by way of the daily message which is automatically | |
| sent about every 24 hours. When the battery voltage is too low, the daily message is replaced | |
| by a Battery Low message. The duration of the daily message is 1.7 seconds. | |
| The transmission of the Daily Message can be disabled by setting the solder bridge B5 (this | |
| does not influence the transmission of the Battery Low message). | |
5.9 | Error Message | |
| The Error Message is sent one time if the device has detected a general dysfunction, or if one | |
| of the following triggering devices remains in its activated position for up to 4 minutes: | |
| – | Call for Help |
| – | Acknowledgement button |
| – | Call for Assistance |
| – | Reserve Call |
|
|
|
i | NOTICE! |
|
The device connected to the Technical Alarm input is allowed to remain in the activated posi- | ||
tion; without transmission of the Error Message. | ||
|
|
|
Bosch Security Systems | User Manual US | 970.035b F.01U.278.521 v2.0 2012.12 |