MIYN46 Wall TransmitterOperation en 21
6.2 | Legend of illustrations | |
|
|
|
| Legend | Description |
|
|
|
|
| The contact of the Call for Help relay is closed |
|
|
|
|
| The contact of the Call for Help relay is open |
|
|
|
|
| The contact of the Call for Help relay opens and closes alternately |
|
|
|
|
| The contact of the Staff Presence relay is closed |
|
|
|
|
| The contact of the Staff Presence relay is open |
|
|
|
|
| The signal lamps are off |
|
|
|
|
| A signal lamp lights up in the indicated color |
|
|
|
|
| A signal lamp flashes in the indicated color |
|
|
|
|
| A signal lamp flashes quickly in the indicated color |
|
|
|
| Table 6.1 |
|
6.3 | Operation with the staff presence processing activated | ||||
6.3.1 | Device behavior when pressing a button |
| |||
| State before action: |
|
|
| |
|
|
|
|
|
|
| Action | State | Relay contact | Signal lamp | Radio Message |
|
|
|
|
|
|
|
|
|
| (none) | |
|
|
|
|
|
|
| Call for Help | Alarm without staff |
|
| Call for Help |
| presence |
|
| ||
|
|
|
|
| |
|
|
|
|
|
|
| Call | Staff presence |
|
| Acknowledgement |
| Acknowledgement | without alarm |
|
| |
|
|
|
| ||
|
|
|
|
|
|
| Call for Assistance | Assistance without |
|
| Call for Assistance |
| staff presence ** |
|
| ||
|
|
|
|
| |
|
|
|
|
|
|
**If the function Assistance only in case of Staff Presence is activated and the MIYN46 Wall Transmitter is not in Staff presence state, the Call for Assistance causes a state Alarm without Staff Presence and a Call for Help radio message.
Bosch Security Systems | User Manual US | 970.035b F.01U.278.521 v2.0 2012.12 |