24 en OperationMIYN46 Wall Transmitter
6.4 | Operation with the staff presence processing deactivated | |||||
6.4.1 | Device behavior upon pressing a button |
|
|
| ||
| State before action: |
|
|
|
| |
|
|
|
|
|
|
|
| Action | State | Relay contact | Signal lamp | Radio Message | |
|
|
|
|
|
|
|
|
|
|
| (none) | ||
|
|
|
|
|
|
|
| Call for Help | Alarm without staff |
|
| Call for Help | |
| presence |
|
| |||
|
|
|
|
|
| |
|
|
|
|
|
|
|
| Call |
|
| Acknowledgement | ||
| Acknowledgement |
|
| |||
|
|
|
|
|
| |
|
|
|
|
|
|
|
| Call for Assistance | Assistance without |
|
| Call for Assistance | |
| staff presence * |
|
| |||
|
|
|
|
|
| |
|
|
|
|
|
|
|
| State before action: Alarm without staff presence |
|
|
| ||
|
|
|
|
|
|
|
| Action | State | Relay contact | Signal lamp | Radio Message | |
|
|
|
|
|
|
|
|
| Alarm without staff |
|
| (none) | |
|
| presence |
|
| ||
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Alarm without staff |
|
| Call for Help | |
| Call for Help | presence |
|
| ||
|
| (unchanged) |
|
|
|
|
|
|
|
|
|
|
|
| Call |
|
| Acknowledgement | ||
| Acknowledgement |
|
| |||
|
|
|
|
|
| |
|
|
|
|
|
|
|
| Call for Assistance | Assistance without |
|
| Call for Assistance | |
| staff presence * |
|
| |||
|
|
|
|
|
| |
|
|
|
|
|
|
|
| State before action: Assistance without staff presence |
|
|
| ||
|
|
|
|
|
|
|
| Action | State | Relay contact | Signal lamp | Radio Message | |
|
|
|
|
|
|
|
|
| Assistance without |
|
| (none) | |
|
| staff presence |
|
| ||
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Assistance without |
|
| Call for Assistance | |
| Call for Help | staff presence |
|
| ||
|
| (unchanged) |
|
|
|
|
|
|
|
|
|
|
|
| Call |
|
| Acknowledgement | ||
| Acknowledgement |
|
| |||
|
|
|
|
|
| |
|
|
|
|
|
|
|
| Call for Assistance | Assistance without |
|
| Call for Assistance | |
| staff presence |
|
| |||
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
970.035b F.01U.278.521 v2.0 2012.12 | User Manual US | Bosch Security Systems |