Bosch Appliances MIYN46 user manual General configuration, Bridge, State, Function

Models: MIYN46

1 28
Download 28 pages 19.7 Kb
Page 16
Image 16
General configuration

16 en InstallationMIYN46 Wall Transmitter

4.7

General configuration

 

The * marks a factory setting.

 

 

 

 

 

Bridge

State

Function

 

 

 

 

 

B3

Open*

Technical Alarms are not repeated.

 

 

 

 

 

B4

Soldered*

Calls are not repeated.

 

 

 

 

 

B5

Open*

A daily message is sent every 24 hours.

 

 

 

 

 

 

Soldered

Daily messages are suppressed.

 

 

 

 

 

B6

Open(o)

Staff Presence Processing is activated.

 

 

Soldered(o)

Staff Presence Processing is disabled.

 

B7

Open*

Activation of J6 [4-5] terminal input causes a Reserve Call.

 

 

 

 

 

 

Soldered

Activation of J6 [4-5] terminal input causes a Call for Assistance.

 

 

 

 

 

B8

Open*

The Assistance Call does not depend on the presence of the Care Per-

 

 

 

sonnel.

 

 

 

 

 

 

Soldered

The Assistance Call is possible only if the Care Personnel has signaled

 

 

 

his/her presence.

 

 

 

 

(o)MIYN46 Wall Transmitters that feature the output relays are delivered with the Staff Pres- ence Processing activated (B6 open). Models that do not feature the output relays are deliv- ered with the Staff Presence Processing disabled (B6 soldered).

970.035b F.01U.278.521 v2.0 2012.12

User Manual US

Bosch Security Systems

Page 16