Appliance details

2Appliance details

2.1GWH 425 PN specifications (Technical data)

Approved in US/Canada

Capacity

GWH 425 PN: 4.3 GPM

Maximum output

GWH 425 PN: 91 525 Btu/hr

Maximum input

GWH 425 PN: 117 000 Btu/hr

Efficiency in %

Recovery efficiency 78%

Min. Output

GWH 425 PN: 23 906 Btu/hr

Gas Requirement

Gas connection (inches) - ¾” NPT

Inlet gas pressure under maximum operation* Propane: 10.5” - 14” water column Natural Gas: 5.7” - 14” water column.

*To measure Gas Pressure, see Measuring Gas Pressure, chapter 3.8.

Venting Natural Draft

Vent diameter (inches) - 5”

Minimum height (feet) - 6’ with no elbows Vertical termination

Sidewall termination only with AQ4 power vent kit.

Water

Hot water connection (inches) - ½” NPT Cold water connection (inches) - ½” NPT

Water valve material: Polymer (PPS) (Polypropylene Sulfid)

Minimum water flow: 0.5 gallon/minute (1.9 l/m)

Minimum recommended water pressure: 30 PSI (2.07 bar)

Connections:

– Bottom of heater

Dimensions

GWH 425 PN:

Depth (in): 8.66” (220 mm)

Width (in): 18.11” (460 mm)

Height (in): 25.79” (655 mm)

Weight: 35 pounds (16 kg).

Gas types

Natural Gas.

LP Gas

Safety devices

Flame failure device (ionization flame rod sensor) Pressure relief valve (supplied with heater)

Over heat prevention (temperature limiter).

Water resistant

IP X4.

6 720 608 034