FLEXIDOME HD

Troubleshooting en 39

 

 

8.2Resolving problems

The following table is intended to help identify the causes of malfunctions and correct them where possible.

Malfunction

Possible causes

Solution

 

 

 

No image

Defective camera.

Connect a local monitor

transmission to

 

to the camera and check

remote location.

 

the camera function.

 

 

 

 

Faulty cable connections.

Check all cables, plugs,

 

 

contacts and

 

 

connections.

 

 

 

 

Incorrect encoder stream

Select the H.264 MP SD

 

property set for

option on the Encoder

 

connection to hardware

Streams configuration

 

decoder.

page.

 

 

 

No connection

The unit's configuration.

Check all configuration

established, no

 

parameters.

image transmission.

 

 

Faulty installation.

Check all cables, plugs,

 

 

contacts and

 

 

connections.

 

 

 

 

Wrong IP address.

Check the IP addresses

 

 

(terminal program).

 

 

 

 

Faulty data transmission

Check the data

 

within the LAN.

transmission with ping.

 

 

 

 

The maximum number of

Wait until there is a free

 

connections has been

connection and call the

 

reached.

transmitter again.

 

 

 

Bosch Security Systems

Installation Manual

AM18-Q0615 v1.0 2012.10

Page 39
Image 39