All operations relative to installation, adjustment and adaptation to another gas type must be carried out by authorized personnel from our Technical Service, and the codes in force, as well as the requisites of the gas companies must be complied with.
4 - Before connecting the appliance, ensure that the local connection conditions, as well as the gas type and pressure match the settings of the appliance.
Ensure that the gas supply is cut off through the manual
The gas connection must be in a place that permits access to the manual
Connect the regulator Figure 3 (2) to the manifold, Figure 3 (1) as shown by the arrow on the regulator applying teflon to the threads.
Connect the pressure regulator to the gas grid using a flexible gas line fitting between the shut- off valve and the pressure regulator. Figure 3.
IMPORTANT INFORMATION
Electrical connection
Before connecting the power cable to the wall outlet, make sure the gas
The voltage and total power must be checked on the specifications plate. This appliance must be grounded.
Always ensure that all connections have been made in accordance with code requirements. Thoroughly follow the requisites of the local electric power company.
The electrical connection (CA
All gas connections must be tested for leaks using an appropriate liquid solution. Never use a flame to test for gas leaks.
Figure 3
1
2
Ensure that a bag containing component 2 is supplied with the appliance. If this component is missing, call our Technical Service. Use the parts we supply to complete the gas connection.
Tighten the appliance regulador to 15 to 22
Connection using a metal pipe. In this case, contact between this tube and the moving parts of the kitchen unit (for example, a drawer) and its passage through areas that could be blocked, must be avoided.
The manufacturer accepts no responsibility for leaks or connections carried out by the installation technician.
Leak testing of the appliance shall be conducted according to manufacturer,s instructions.
WARNING: this appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle.
Do not cut or remove the grounding prong from this plug.
The current supply connection cable must be at least of the JT 3x18 AWG/UL/CSA variety, or should be
The mains connecting cable must only be purchased through and connected by an authorised specialist.
Do not tamper with the inside of the appliance. If this is necessary, call our technical assistance service.
18