Bosch Appliances SHE660, SHE990, SHY660, SHV570, SHX570 installation instructions Max

Models: SHY660 SHV570 SHE660 SHE990 SHX570

1 21
Download 21 pages 28.42 Kb
Page 6
Image 6

30 _E

(762mm)

21 EE

(533mm)

Figure 4

Dishwasher E_ectrica_ Rating

VeltsAmperes Watts

120 60 15 1,450

(max)

3" A,, 1

( 75mm ° lOOmm1.

3/8"-

1/2"

_

I

.<

( 8mm-

13mm)

 

 

Figure

5

 

 

Electrical Shock Hazard

To avoid electdcaJ shock, do not work on an energized circuit. Doing so could resuJt in serious injury or death. Onty qualified electricians should perform electrical work. Do not attempt any work

on the dishwasher etectric suppty circuit until you are certain the circuit is

de-energized.

Fire Hazard

To avoid a fire hazard, make sure electrical work is properly installed. OnJy qualified electricians shouJd perform eJectrical work.

Electrica! Supply

The customer has the responsibility of ensuring that the dishwasher electrical installation is in compliance with all national and local electrical codes and ordinances. The dishwasher is designed for an electrical supply of 120V, 60 Hz, AC, connected to a dishwasher-dedicated, properly grounded electrical circuit with a fuse or breaker rated for 15 amps. Electrical supply conductors shall be a minimum #14 AWG copper wire rated at 75°C or higher.

Regardless of where the electrical supply cable enters the enclosure, position the cable 21" (533mm) from the enclosure's left side, as shown in Figure 4. Extend the cable 30" (762mm) from the enclosure's back, as shown in Figure 4.

Remove 3" =4" (75mm =lOOmm) of the cable'souter casing, as shown in Figure 5, then remove 3/8" - 1/2" (9 - 13mm) of insulation from each wire, as shown in Figure 5.

Page 6