SC & SI Remote Interface Description en | 12
Bosch Security Systems B.V. | 2003 December | SC & SI Remote Interface Description
1..MAX_CARD_CODE. This is the numeric code
present on the identification card handed over to the
delegate and which is to be used in combination with
attendance registration and access control.
lPin Delegate pincode. A numeric value in the range
111..555551. PIN codes are used for attendance
registration and access control, but do not have to be
unique.
wUnitNr The unit number that the delegate is assigned to by
default. This unit number must equal UnitId retrieved
with SC_C_GET_CCU_CONFIG
iDeskLang Delegate display language. One of:
DCNC_VER_ENGLISH
DCNC_VER_FRENCH
DCNC_VER_GERMAN
DCNC_VER_ITALIAN
DCNC_VER_SPANISH
DCNC_VER_SIXTH
lVWeight Delegate vote weight. A value in the range
1..MAX_VOTE_WEIGTH to be used by the voting
application.
bMicAut TRUE: this delegate has microphone authorisation.
FALSE: this delegate has no micro. authorisation
bVotingAut TRUE: this delegate has voting authorisation.
FALSE: this delegate has no voting authorisation
bInterAut TRUE: this delegate has intercom authorisation.
FALSE: this delegate has no intercom authorisation.
szSLine Delegate screenline. A string to represent a delegate
e.g. on a Hall Display.
If more than DQSC_MAX_N_DL_DEL_REC records should be send to the CCU, more calls of this remote
function will be needed. In this case the ‘bFirstCluster’ and ‘bLastCluster’ indicate the start and termination of
the complete delegate database download.
Response structure from the function
The function has no response parameters.
Error codes returned
DQSE_NOERROR
DQSE_SET_PINSIZE_FAILED (when pincode size update fails)
DQSE_DELEGATE_LIST_TOO_BIG (when iFillLevel is greater than
DQSC_MAX_N_DL_DEL_REC)
DQSE_INSERT_DELEGATE_FAILED (when delegate insert failed)
DQSE_DELEGATE_DATA_BLOCKED
DQSE_APP_NOT_STARTED
Related functions
SC_C_START_DQS
SC_C_DOWNLOAD_CCU_DB
SC_C_CLEAR_CCU_DB
SC_C_CCU_APPLY_ONE
3.10 SC_C_DOWNLOAD_CCU_DB
Purpose
This function is equal to SC_C_MAINT_CCU_DB except that it does not contain a field for the delegates
screenline in the parameter structure.
1 Although the PIN code is identified as a variable of the type ‘long’, the real PIN code is a 6-based number. This means
that only digits 1 - 5 are allowed to be part of the PIN code. Besides, the PIN code also depends on the iPinSize variable.
If e.g. iPinSize is 3, the possible values for lPin range from 111 to 555. If iPinSize is 5 then lPin ranges from 11111 to
55555. So, lPin must always contain iPinSize digits in the range 1..5.