DIMENSIONS

EXTERIOR

TERMINATION

Figure 1

Maximum Hydrostatic water pressure - 1.03 MPa (150 p.s.i.)

Maximum recommended working pressure - 0.69 MPa (100 p.s.i.)

Minimum working pressure - 0.09 MPa (13 p.s.i.) no piping attached

Reccomended pressure for showers and domestic, 0.27 MPa (40 p.s.i.)

Model

Type of Gas

Altitude

Input

Main Burner Orifices

 

 

 

 

Size, mm

Qt.

 

natural gas

standard

130 000 Btu/hr (38 kW)

1.20 diam.

18

WR430-7.K..

propane/LP

(0 - 2 000 ft)

125 000 Btu/hr (36.6 kW)

0.79 diam.

18

natural gas

high *

117 000 Btu/hr (34.3 kW)

1.20 diam.

18

 

 

propane/LP

(2 000 - 4 500 ft)

112 000 Btu/hr (32.8 kW)

0.79 diam.

18

The high altitude ratings listed are Canadian Gas Association high altitude ratings and are valid only in Canada. In the U.S., the National Fuel Gas Code, ANSI Z223.1-1988, recommends for high altitude installations above 2,000 feet, that the input rate be reduced 4% for each 1,000 feet above sea level. - See page 15.