DIMENSIONS
EXTERIOR
TERMINATION
Figure 1
Maximum Hydrostatic water pressure - 1.03 MPa (150 p.s.i.)
Maximum recommended working pressure - 0.69 MPa (100 p.s.i.)
Minimum working pressure - 0.09 MPa (13 p.s.i.) no piping attached
Reccomended pressure for showers and domestic, 0.27 MPa (40 p.s.i.)
Model | Type of Gas | Altitude | Input | Main Burner Orifices | ||
|
|
|
| Size, mm | Qt. | |
| natural gas | standard | 130 000 Btu/hr (38 kW) | 1.20 diam. | 18 | |
propane/LP | (0 - 2 000 ft) | 125 000 Btu/hr (36.6 kW) | 0.79 diam. | 18 | ||
natural gas | high * | 117 000 Btu/hr (34.3 kW) | 1.20 diam. | 18 | ||
| ||||||
| propane/LP | (2 000 - 4 500 ft) | 112 000 Btu/hr (32.8 kW) | 0.79 diam. | 18 |
•The high altitude ratings listed are Canadian Gas Association high altitude ratings and are valid only in Canada. In the U.S., the National Fuel Gas Code, ANSI
6 720 606 599 | 3 |