Technical Data
235/8''
(600 mm)
221/4''
(565 mm)
33 1/2'' (850 mm) adjusts to
34 1/2'' (876 mm)
WTA 3510: 88 lbs. (40 kg) ± with packaging 199 lbs. (45 kg)
WTL 5410: 99 lbs. (45 kg) ± with packaging 110 lbs. (50 kg)
Figure 12.
Electrical Requirements
The Bosch dryers should be CONNECTED TO AN 30A INDIVIDUAL BRANCH CIRCUIT. North American models have the following electrical rating:
Model | Volts | Hertz | Amperes | Watts |
|
|
|
| (max.) |
|
|
|
|
|
WTA | 208/240 | 60 | 13 | 3,100 |
3510 |
|
|
|
|
WTL | 208/240 | 60 | 13 | 3,100 |
5410 |
|
|
|
|
|
|
|
|
|
Check the rating plate on the dryer to make sure your machine has this rating.
Choosing the Location
The dryer should not be installed:
in an area exposed to dripping water or outside weather conditions
in an area where it (and in the case of the WTA 3510, its exhaust duct) will come in contact with combustible materials, such as curtains, drapes
or paper.
in areas where water may freeze
in an area where gasoline or other flammables are kept or stored.
Check local codes before choosing a location. Some codes do not permit installation of a clothes dryer in a garage, closet, mobile home or sleeping area. Your local building inspector should be able to advise you of the codes in your area.
Minimum | Installation Clearances | ||
|
|
| |
| Alcove or Under | Closet | |
| Counter |
| |
|
|
|
|
Sides | 0'' ( | 0 mm) | 0'' ( 0 mm) |
Top | 0'' ( | 0 mm) | 10'' (250 mm) |
Rear | 1'' (25 mm) | 5'' (125 mm) | |
|
|
|
|
Ventilation Requirements
| Alcove or | Closet |
| Under |
|
| Counter |
|
|
|
|
WTA | Ensure air flow | Closet door must have |
3510 | of | 2 (louvered) openings, |
| 112 cu.ft./min | each having a minimum |
| (3,2 cu.m./min) | area of 60 sq. inches |
| through dryer | (387 sq. cm.), located |
|
| 3 inches (8 cm) from |
|
| bottom and top of door. * |
WTL | Ensure air flow | Closet door must remain |
5410 | of | open during dryer |
| 118 cu.ft./min | operation. |
| (3,3 cu.m./min) |
|
| through dryer |
|
|
|
|
* A louvered door with equivalent air opening is acceptable.
Flooring
The dryer should be installed on a level, solidly constructed floor. DO NOT install the dryer on a carpeted floor.
17