INSTALLATION

Step 1

Unpack the Dryer

Carefully remove the packing material from the outside of the dryer.

Step 2

Inspect the Dryer

Thoroughly inspect the dryer, prior to installation, for possible freight or cosmetic damage.

Step 3

Position Dryer near Installation Area

Move the dryer so that it is within four feet of the desired position.

Note: Corrugated packing material may be used to protect the floor. Do not use corrugated material with staples.

Step 4 Exhaust Duct

(Model WTA 3510 only!)

The WTA 3510 must be exhausted to the outdoors.

￿WARNING

1.To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.

2.DO NOT use non-metal duct with this dryer.

3.DO NOT use duct smaller than 4 inches in diameter.

4.DO NOT use exhaust hoods with magnetic latches.

5.DO NOT exhaust the dryer into a chimney, furnace cold air duct, attic, crawl space, or any other ductwork used for venting.

6.DO NOT install flexible duct in an enclosed wall, ceiling or floor.

7.DO NOT crush or kink the duct.

8.Do clean and inspect the exhaust system on a regular basis; once a year, at a minimum.

9.The exhaust duct must end with swing out damper(s).

Be sure to install the exhaust according to all governing codes and ordinances. Rigid metal duct is recommended for venting this dryer. If flexible metal duct is used, be sure it is fully supported when the dryer is in its final position. Excess ducting should be trimmed off to avoid sagging or kinking of the ductwork.

The duct may be connected to the left, right or back of the WTA 3510, electric vented dryer. If connecting to the left or right hand side of the dryer, remove the sealing cover from the side to be used, as shown in Figure 14.

Figure 14.

The sealing cover should then be placed over the open vent opening at the back of the dryer, as shown in Figure 15.

Figure 15.