Pedal Settings (Control/Expression)
38
Parameter Value Explanation
[7] WAVE RATE
*1
0–100, BPM
This determines the time spend
for one cycle of the assumed EXP
Pedal.
When set to BPM, the value of each parameter will
be set according to the value of the “Master BPM”
specied for each patch. This makes it easier to
achieve eect sound settings that match the tempo
of the song.
* If, due to the tempo, the time is longer than the
range of allowable settings, it is then synchro-
nized to a period either 1/2 or 1/4 of that time.
[8] WAVEFORM
*1
SAW
TRI
SINE
Page 4
[5]
INT PDL
TRIGGER
*2
PATCH CHANGE This is activated when a patch is
selected.
EXP PDL-LO
This is activated when the GT-100’s
[EXP] pedal is set to the minimum
position.
EXP PDL-MID
This is activated when the GT-100’s
[EXP] pedal is moved through the
middle position.
EXP PDL-HI
This is activated when the GT-100’s
[EXP] pedal is set to the maximum
position.
EXP PDL SW This is activated when the EXP
pedal switch is operated.
P.LOOP PEDAL This is activated when the
[PHRASE LOOP] pedal is operated.
ACC/CTL PDL This is activated when the [ACCEL/
CTL] Pedal is operated.
SUB EXP PDL
This is activated when an external
expression pedal connected to
the SUB CTL 1, 2/SUB EXP jack is
operated.
SUB CTL1 PDL
This is activated when an external
footswitch connected to the SUB
CTL 1, 2/SUB EXP jack is operated.
SUB CTL2 PDL
This is activated when an external
footswitch connected to the SUB
CTL 1, 2/SUB EXP jack is operated.
CC#1–#31 This is activated when a control
change is received.
CC#64–#95 This is activated when a control
change is received.
[6] INT PDL TIME
*2 0–100
This species the time over which
the internal pedal will move from
the toe-raised position to the
toe-down position.
[7]
INT PDL
CURVE
*2
LINEAR
SLOW RISE
FAST RISE
*1 The WAVE RATE and WAVEFORM parameters are enabled when the
Source parameter is set to WAVE PEDAL.
*2 The INT PDL TRIGGER, INT PDL TIME, and INT PDL CURVE parameters are
enabled when the SOURCE parameter is set to INT PEDAL.
About the Range of a Target’s Change

The value of the parameter selected as the target changes

within the range dened by “Min” and “Max,” as set on the

GT-100.

When using an external footswitch, or other controller that

acts as an on/o switch, “Min” is selected with O (CLOSED),

and “Max” is selected with On (OPEN).

When using an external expression pedal or other controller

that generates a consecutive change in the value, the value

of the setting changes accordingly, within the range set by

the minimum and maximum values. Also, when the target

is of an on/o type, the median value of the received data is

used as the dividing line in determining whether to switch it

on or o.

When using the footswitch:
Allowable
Parameter
Settings Range
OFF ON
MAX
MIN
When using the expression pedal:
When the pedal is
fully raised
When the pedal is
fully advanced
Allowable
Parameter
Settings Range
0 127
MAX
MIN
When controlling the On/O target with the expression pedal:
Value
ON
OFF
When the pedal is
fully raised
When the pedal
is advanced
halfway
When the pedal
is fully advanced
Degree to
Which Expres-
sion Pedal Is
Depressed
0 127

* The range that can be selected changes according to the

target setting.

* When the “minimum” is set to a higher value than the

“maximum,” the change in the parameter is reversed.

* “The values of settings can change if the target is changed

after the “minimum” and “maximum” settings have been

made. If you’ve changed the target, be sure to recheck the