ELECTRICALGROUNDINGINSTRUCTIONS: (continued)

DUTY CYCLE:

Toensure long life of your BOSTITCHair compressor,do not operateon more than a 50% duty cycle. If this air compressor pumpsair more than 50% of one hour,then the compressor’s capability is less than the air delivery requiredby the application. Alwaysmatchthe air volume requirements of the attachmentor accessorywith the air volumedeliveryof the compressor.

Notice!: BOSTITCH does not recommend the use of extension cordswith compressors. The use of an extension cord can resultin the loss of voltagesuppliedto the compressorwhich could prevent the compressor from starting. For optimum performance,plug the compressor directly into an outlet and increase the lengthof airlineas needed.

If an extension cord must be used,use theseguidelines:

Distance Needed

RecommendedGauge

Less than 25 ft.

12 Gauge

25 - 50 ft.

10 Gauge

Greater than 50 ft.

Not Recommended

CAP1512-OF

SPECIFICATIONS

Motor:

2HP (Peak)/ 1.5HP(Running)

 

115V – 60HZ

Fuse Requirements:

15 Amps minimum

OperatingPressure:

0 – 150PSI

SafetyValveSetting:

160 PSI

Air Delivery:

3.7 CFM @ 40 PSI

 

2.8 CFM @ 90 PSI

MaximumAmps at WorkingPressure:

12

TankSize:

1.2 Gallons

Air Outlet:

1/4" NPT

PressureSwitchSettings:

On @ 120 PSI

 

Off @ 150 PSI

Weight:

22lbs.

PSI = PoundsPer SquareInch:

CFM = CubicFeet Per Minute

6

Page 6
Image 6
Bostitch CAP1512-OF manual Electricalgroundinginstructions, Specifications