Troubleshooting (continued)

Regarding The Indicator Lamps

Lighting and flashing of the STANDBY/ON indicator, the LAMP indicator, and the TEMP indicator have the meanings as described in the table below. Please respond in accordance with the instructions within the table. If the same indication is displayed after the treatment, or if an indication other than the following is displayed, please contact your dealer or service company.

NOTE • When the interior portion has become overheated, for safety purposes, the power source is automatically turned off, and the indicator lamps may also be turned off. In such a case, press the “” (OFF) side of the main power switch, and wait at least 45 minutes. After the projector has sufficiently cooled down, please make confirmation of the attachment state of the lamp and lamp cover, and then turn the power on again.

STANDBY/ON

LAMP

TEMP

Description

indicator

indicator

indicator

 

Lighting

Turned

Turned

The projector is in a standby state.

in Orange

off

off

Please refer to the section “Power On/Off”.

 

 

 

 

Blinking

Turned

Turned

The projector is warming up.

in Green

off

off

Please wait.

 

 

 

 

Lighting

Turned

Turned

The projector is in an on state.

in Green

off

off

Ordinary operations may be performed.

 

 

 

 

Blinking

Turned

Turned

The projector is cooling down.

in Orange

off

off

Please wait.

 

 

 

 

 

 

 

The projector is cooling down. A certain error has

Blinking

(discre-

(discre-

been detected.

Please wait until the STANDBY/ON indicator finishes blink,

in Red

tionary)

tionary)

and then perform the proper response measure using the

 

 

 

 

 

 

item descriptions below as reference.

 

 

 

 

 

 

 

The lamp does not light, and there is a possibility

 

 

 

that interior portion has become heated.

 

 

 

Please turn the power off, and allow the unit to cool down at

 

 

 

least 20 minutes. After the projector has sufficiently cooled

Lighting

Lighting

Turned

down, please make confirmation of the following items, and

then turn the power on again.

in Red

in Red

off

• Is there blockage of the air passage aperture?

 

 

 

 

 

 

• Is the air filter dirty?

 

 

 

• Does the peripheral temperature exceed 35°C?

 

 

 

If the same indication is displayed after the treatment,

 

 

 

please change the lamp by referring to the section “Lamp”.

 

 

 

 

 

 

 

(This table is continued to the following page.)

43

Page 44
Image 44
BOXLIGHT MP-57i, MP-58i user manual Regarding The Indicator Lamps