Honeywell Gas Control Testing, Disassembly, and Replacement

Manual backgroundManual backgroundTheManual background BradfordManual backgroundManual backgroundManual backgroundWhite

Manual backgroundDEFENDER

Safety System®

SERVICE PROCEDURE RG-VI

Gas Control

Testing, Disassembly & Replacement (Honeywell)

Honeywell Gas Control Testing, Disassembly, and Replacement

The Gas Control is made up of (5) major components; the control cover, the piezo igniter, the valve body, the temperature sensor, and the back plate. The Gas Control is designed so that any of these components may be replaced without replacing the entire Gas Control.

Gas Control

Valve Body

Backplate

 

 

Cover

 

 

Gas Control

Cover Screw

 

 

Temperature

Piezo Igniter

 

Sensor

 

Valve Body

Insertion Stick

 

Screw

 

 

LINE PRESSURE

The Gas Control is designed for a maximum line pressure of 14.0" w.c. and a minimum line pressure of 1.0" w.c. over the water heater’s rated manifold pressure (check rating plate). Line pressure must be checked with the main burner on and off to assure proper readings.