GAS CONTROL DISASSEMBLY/REASSEMBLY
Rotate knob counter-clockwise
to the “OFF” posistion.

Gas Control cover screwValve body pinsTheManual background BradfordManual backgroundManual backgroundManual backgroundManual backgroundWhite

Manual backgroundDEFENDER

Safety System®

SERVICE PROCEDURE RG-VI

Gas Control

Testing, Disassembly & Replacement (Honeywell)

GAS CONTROL DISASSEMBLY/REASSEMBLY

Step 1. Rotate knob of the Gas Control to the “OFF” position.

Step 2. Turn off gas supply to water heater.

Step 3. Disconnect gas supply line from Gas Control.

Step 4. Disconnect piezo igniter wire.

Step 5. Remove inner door assembly following SERVICE PROCEDURE RG-I, steps 1 through 3c. Step 6. Remove Gas Control cover screw.

Gas Control cover screw

Step 7. Depress both tabs on the top of the Gas Control cover and pull to remove.

Manual backgroundManual backgroundCAUTION

Use caution not to bend or damage valve body pins when removing or installing Gas Control cover.

Valve body pins

24