Henny Penny OFG-392 Continued, Replacement, POWER switch to OFF and disconnect main circuit

Models: OFG-392

1 80
Download 80 pages 9.11 Kb
Page 20
Image 20
(Continued)

 

Model OFG- 390

2-4. HIGH TEMPERATURE

 

LIMIT CONTROL

 

(Continued)

 

Replacement

To avoid electrical shock or property damage, move the

 

POWER switch to OFF and disconnect main circuit

 

breaker, or unplug cord at wall receptacle.

1.

If the tube is broken or cracked, the control will open,

 

shutting off electrical power. The control cannot be reset.

2.

Drain shortening from the frypot and discard. Asubstance

 

in the tube could contaminate the shortening.

3.

Remove control panel.

4.

Loosen small inside screw nut on capillary tube.

5.

Remove capillary bulb from bulb holder inside the frypot.

6.

Straighten the capillary tube.

7.

Remove larger outside nut that threads into pot wall, and remove

 

defective control from control panel area.

8.

Insert new control and replace screws.

9.

Uncoil capillary line, starting at capillary tube, and insert

 

through frypot wall.

 

To avoid electrical shock or other injury, run the capillary

 

line under and away from all electrical power wires and

 

terminals. The tube must never be in such a position where

 

it could accidentally touch the electrical power terminals.

10.

Carefully bend the capillary tube as shown in photo and place

 

into bulb brackets.

2-3

1003

Page 20