| Model OFG- 390 |
| |
LIMIT CONTROL |
|
(Continued) |
|
Replacement | To avoid electrical shock or property damage, move the |
| POWER switch to OFF and disconnect main circuit |
| breaker, or unplug cord at wall receptacle. |
1. | If the tube is broken or cracked, the control will open, |
| shutting off electrical power. The control cannot be reset. |
2. | Drain shortening from the frypot and discard. Asubstance |
| in the tube could contaminate the shortening. |
3. | Remove control panel. |
4. | Loosen small inside screw nut on capillary tube. |
5. | Remove capillary bulb from bulb holder inside the frypot. |
6. | Straighten the capillary tube. |
7. | Remove larger outside nut that threads into pot wall, and remove |
| defective control from control panel area. |
8. | Insert new control and replace screws. |
9. | Uncoil capillary line, starting at capillary tube, and insert |
| through frypot wall. |
| To avoid electrical shock or other injury, run the capillary |
| line under and away from all electrical power wires and |
| terminals. The tube must never be in such a position where |
| it could accidentally touch the electrical power terminals. |
10. | Carefully bend the capillary tube as shown in photo and place |
| into bulb brackets. |
1003 |