Henny Penny OFG-392 Ignitor Assembly, Toavoid Injury, Property Damage, Or, Valve Do The Following

Models: OFG-392

1 80
Download 80 pages 9.11 Kb
Page 36
Image 36
2-19. IGNITOR ASSEMBLY

 

Model OFG- 390

2-19. IGNITOR ASSEMBLY

The 390 has electronic spark ignition, that lights a standing pilot.

Replacement

1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the POWER switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

TOAVOID INJURY, PROPERTY DAMAGE, OR

EXPLOSION, BEFORE REPLACING GAS CONTROL

VALVE DO THE FOLLOWING:

MOVE THE POWER SWITCH TO THE OFF POSITION.

DISCONNECT THE MAIN CIRCUIT BREAKER AT THE WALL, OR UNPLUGTHE POWER CORD.

TURN OFF THE MAIN GAS SUPPLYTO THE FRYER AND DISCONNECTAND CAPTHE SUPPLY LINE TO FRYER, OR POSSIBLE.

2.Remove the control panel as discussed in Complete Control Panel Section.

3.Disconnect the 1/4” gas line fitting from the pilot assembly.

4.Follow the wire from the spark ignitor to the module, and remove the wire from the module.

5.Remove the left, or right side panel, depending upon which ignitor assembly to be removed.

6.Disconnect gas line (for the left ignitor assembly).

7.Remove the 4 screws securing the burner assembly, and pull the assembly from the unit.

8.Using a Phillips head screwdriver, remove the screw securing the ignitor assembly to the burner assembly, and pull the ignitor assembly from the unit.

9.Secure the new assembly with the screw previously removed, making sure the assembly is turned to provide a 1/8” gap be- tween the spark ignitor and the hood of the pilot assembly.

2-19

1003

Page 36
Image 36
Henny Penny OFG-392 Ignitor Assembly, Toavoid Injury, Property Damage, Or, Explosion, Before Replacing Gas Control