Model OFG- 390
(Continued) |
|
|
| 5. | Remove the flue. |
| 6. | Disconnect wires at junction box. |
| 7. | Remove the blower from the plate. |
| 8. | Replace new blower in reverse order of procedures. |
| The transformer reduces the voltage down to accommodate | |
| those components with low voltage. | |
| 1. | Remove electrical power supplied to the unit. |
|
| To avoid electrical shock or property damage, move the |
|
| POWER switch to OFF and disconnect main circuit |
|
| breaker, or unplug cord at wall receptacle. |
| 2. | Remove the control panel. |
| 3. | Remove the two (2) screws securing the transformer to the |
|
| unit and remove transformer. |
| 4. | Remove the wires from transformer. |
|
| Mark wires before removal to insure new transformer is |
|
| wired correctly. |
| 5. | Replace with new transformer in reverse order. |
1003 |
|