2-14. DRAIN VALVE

 

Model OFG- 390

2-14. DRAIN VALVE

The drain valve opens when the drain valve handle is pulled out

AND EXTENSION

and drains the shortening out of the pot.

Replacement

1. Using a 3/8” socket, remove the nuts securing the drain switch

 

bracket, and pull the bracket from the studs.

2.Remove the nut securing the drain handle and pull the handle from the drain valve.

3.Using a large adjustable wrench, unscrew the drain valve and extension from the unit.

4.Replace the drain valve and extension.

5.Replace the drain switch bracket.

6.Adjust the microswitch to be no more than 1/8” (3 mm) from the shaft of the drain valve.

NOTE: Listen for click of switch while pulling drain valve handle.