| Model OFG- 390 |
| The gas control valve sends regulated gas to the burners when the |
| controller calls for heat. The control valve can be turned on |
| or off. In the on position, and the power switch on, a spark ignitor |
| lights a standing pilot, and when the control calls for heat, the valve |
Safety Precautions | is opened and the burners are ignited. |
|
TOAVOID INJURY, PROPERTY DAMAGE, OR
EXPLOSION, BEFORE REPLACING GAS CONTROL
VALVE DO THE FOLLOWING:
•MOVE THE POWER SWITCH TO THE OFF POSITION.
•DISCONNECT THE MAIN CIRCUIT BREAKER AT THE WALL, OR UNPLUGTHE POWER CORD.
•TURN OFF THE MAIN GAS SUPPLYTO THE FRYER AND DISCONNECTAND CAPTHE SUPPLY LINE TO FRYER, OR POSSIBLE.
Replacement
A voltage check at the gas control valve must be taken four (4) seconds after the POWER switch is turned to the ON position.
1.Turn gas knob to the OFF position.
2.Remove cover from control valve.
3.Remove the wires from the control valve.
1003 |