Bradford-White Corp IGE-199R Series Minimum Installation Clearances, Build Opening Clearances Fig

Models: IGE-199R Series IGE-199C Series

1 44
Download 44 pages 36.88 Kb
Page 10
Image 10
Build Opening Clearances (Fig 1)

Build Opening Clearances (Fig 1)

Table 1

Minimum Installation Clearances

Reference

Description

Minimum Distance

in Inches (cm)

 

 

A

Vertically below a window, door which opens, air inlet

12” (30.5 cm)

B

Vertically above a window, door which opens, air inlet

12” (30.5 cm)

C

Below eaves, porches, or overhangs

36” (91.4 cm)

D

Horizontally from a window, door which opens, air inlet

12”

(30.5 cm)

E

Horizontal distance from another water heater

2”

(5.1 cm)

F

Vertical distance from another water heater

12 (30.5 cm)

REMOVE CARTON

Move water heater to a location near where it will be installed. Carefully slide water heater out from the carton and remove all the contents.

MOUNT WATER HEATER ON THE WALL

The EVERHOTIGE series water heater must be installed outdoors. Refer to Table 1 clearances under overhangs, windows, doors, etc. Also avoid locations where there is heavy water runoff from roofs. Determine the proper height and location for the water heater to be installed. Consider the water and gas connections. Allow enough room for servicing the water heater and maintain the clearances from combustible materials previously stated. The water heater is supported on the wall by means of a top and bottom slotted angle bracket. For convenience, the center hole of the bracket is slotted so that a center screw may be first installed in the wall for hanging the water heater on the wall. Two more screws are then added on the ends of the bracket to secure the water heater. Wall anchors should be used for the bracket holes unless the bracket lines up with a stud. As an alternative, a suitable piece of plywood or 2x4 wooden support may be cut to span the wall studs and the brackets. Make sure the anchors are rated to support the 50 pound (23 kg) weight of the water heater.

10

Page 10
Image 10