Bradford-White Corp IGE-199R Series Commercial Models see Figure, F Priority, Set Temperature

Models: IGE-199R Series IGE-199C Series

1 44
Download 44 pages 36.88 Kb
Page 32
Image 32
Commercial Models (see Figure 11):

Commercial Models (see Figure 11):

1.Commercial models are supplied in the water heater carton with a Remote Main Control, which will allow the outlet water temperature to be adjusted from 98-185°F. When additional Remote Controls are installed, the temperature can only be adjusted on the remote control that has the Priority Indicator Light glowing. The temperature displayed on the control in use will also be displayed on all the other remote controls.

2.All hot water faucets must be off to get the full range of temperature adjustment. The control will only allow an adjustment range of 98-110°F while hot water is in use to prevent scalds. If there are other Remote Controls installed, press the “Priority” button on the control you want to change the setting on and the yellow “Priority” indicator light will glow.

3.Press the “H” or “C” buttons until the desired temperature is shown on the display.

4.The water heater will automatically start heating water whenever a hot water faucet is opened. The remote temperature control(s) will indicate hot water use with the green “IN USE” indicator.

5.All controls can also display diagnostic error codes, water flow rate through the unit (in gallons per minute) and the outlet water temperature.

6.Pressing the “Priority Button” followed by the “H” button will display a sequence of up to 9 error codes, if any, stored in memory that has been experienced. Any error codes will be displayed on the digital monitor in sequence starting with the most recent code.

7.To display the water flow through the water heater with hot water in use, depress the “H” button for 2 seconds and then simultaneously press the “P” button. (GPM = Display Readout X 0.1).

8.To display the outlet water temperature while in use, depress the “C” button for 2 seconds and then simultaneously press the “P” button.

°F

Priority

Set Temperature

In Use

 

Main Controller 239-44509-00

endless hot water system

CAUTION: Hotter water increases the risk of scald injury. Before changing temperature setting, see instruction manual.

Control for Commercial Models (Fig 11)

32

Page 32
Image 32
Bradford-White Corp IGE-199R Series Commercial Models see Figure, Control for Commercial Models Fig, F Priority, In Use