ACCESSORIES

Stainless Steel Adjustable Legs

Floor Mounting Hardware

1. Carefully place the unit on its side.

Stainless steel adjustable legs with deck mounting flange are

 

 

 

available for securing the booster heater to the floor.

 

NOTICE

 

Shock Absorber

Do not lay unit on the side with the control panel. Damage

The shock absorber installed between the booster and the

to the unit could occur.

commercial dish machine reduces water hammer induced by

2. Thread the adjustable legs into the existing leg holes on

rapidly operating valves. The water hammer can cause damage

the bottom of the unit.

to the equipment.

3. After all legs are secure, return the unit to the upright

Blended Phosphate Water Treatment

position.

System

NOTE: If unit is not level, use an adjustable open-end wrench

The Blended Phosphate Water Treatment System is installed

to adjust the foot of each leg until unit is level. Each leg

before the booster water heater and reduces mineral scale

is adjustable from 6″ (152 mm) to 7″ (178 mm).

build-up by introducing a measured amount of polyphosphate

into the water.

 

 

 

Bradford White recommends that the Blended Phosphate Water

 

 

 

Treatment System be installed with unions on the incoming 3/4"

 

 

 

water supply line after the pressure reducing valve and before

 

 

 

the booster water heater.

 

 

 

Cartridges supplied have a usage rating of 100,000 gallons

 

 

 

(378,541 liters) of water. To assure proper operation the

 

 

 

cartridges must be replaced when expired.

 

 

 

NOTE: Product failure caused by liming or sediment buildup is

Figure 14. Optional Stainless Steel Adjustable Legs

not covered under warranty.

 