SPECIFICATIONS

Circuit Breaker and Fused Disconnect Switch Sizes — 36 to 57 kW

Model

 

kW

 

Volts

 

Phase

 

Amp Draw

 

 

Breaker or

 

Copper

 

Conduit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fuse Size

 

Wire Size

 

Size

 

 

 

 

 

 

 

L1

 

L2

 

L3

 

 

LI6363CFC

 

36

 

208

 

1

173

 

173

 

-

 

225

 

4/0

 

1-1/2" (38 mm)

LI6363CFD

 

36

 

208

 

3

100

 

100

 

100

 

125

 

1

 

1-1/4" (32 mm)

LI6363CFE

 

36

 

240

 

1

150

 

150

 

-

 

200

 

3/0

 

1-1/2" (38 mm)

LI6363CFF

 

36

 

240

 

3

86.7

 

86.7

 

86.7

 

125

 

1

 

1-1/4" (32 mm)

LI6363CFM

 

36

 

480

 

3

43.3

 

43.3

 

43.3

 

60

 

6

 

3/4" (19 mm)

LI6453CFD

 

45

 

208

 

3

125

 

125

 

125

 

175

 

2/0

 

1-1/2" (38 mm)

LI6453CFE

 

45

 

240

 

1

188

 

188

 

-

 

250

 

250 kcmil

 

2" (51 mm)

LI6453CFF

 

45

 

240

 

3

108

 

108

 

108

 

150

 

1/0

 

1-1/4" (32 mm)

LI6453CFM

 

45

 

480

 

3

54

 

54

 

54

 

70

 

4

 

1" (25 mm)

LI6543CFD

 

54

 

208

 

3

150

 

150

 

150

 

200

 

3/0

 

2" (51 mm)

LI6543CFF

 

54

 

240

 

3

130

 

130

 

130

 

175

 

2/0

 

1-1/2" (38 mm)

LI6543CFM

 

54

 

480

 

3

65

 

65

 

65

 

90

 

3

 

1" (25 mm)

LI6573CFD

 

57

 

208

 

3

158.4

 

158.4

 

158.4

 

200

 

3/0

 

2" (51 mm)

LI6573CFF

 

57

 

240

 

3

137.3

 

137.3

 

137.3

 

175

 

2/0

 

1-1/2" (38 mm)

LI6573CFM

 

57

 

480

 

3

68.6

 

68.6

 

68.6

 

90

 

3

 

1" (25 mm)

Wire size is based on

 

THHN wire

 

for branch circuit protection at .91 derate

factor. Circuit breakers and fused disconnects are to

be mounted remote and wired by contractor. Sizes are based on the 2002 NEC table 310-16. Conduit size based on conductors

plus ground wire sizing per Table C1 from Appendix C.

 

 

 

 

 

 

 

 

 

 

NOTE: 250 kcmil maximum wire size for terminal block.

 

 

 

 

 

 

 

WARNING! Consult a licensed electrical contractor for proper electrical installation conforming to local electrical codes

and the National Electrical Code (N.E.C.).

 

 

 

 

 

 

 

 

 

 

 

Capacity

kW

40°F (22°C) Rise

70°F (39°C) Rise

Shipping Weight

Model

LI663XXX Models

6

60 gph (227 lph)

34 gph (129 lph)

118 lbs. (54 kg)

LI693XXX Models

9

90 gph (341 lph)

52 gph (197 lph)

118 lbs. (54 kg)

LI6123XXX Models

12

120 gph (454 lph)

69 gph (261 lph)

120 lbs. (54 kg)

LI6153XXX Models

15

151 gph (572 lph)

86 gph (326 lph)

120 lbs. (54 kg)

LI6183XXX Models

18

181 gph (685 lph)

103 gph (390 lph)

120 lbs. (54 kg)

LI6243XXX Models

24

241 gph (912 lph)

138 gph (522 lph)

142 lbs. (64 kg)

LI6303XXX Models

30

301 gph (1139 lph)

172 gph (651 lph)

142 lbs. (64 kg)

LI6363XXX Models

36

361 gph (1367 lph)

206 gph (780 lph)

142 lbs. (64 kg)

LI6453XXX Models

45

452 gph (1711 lph)

258 gph (977 lph)

142 lbs. (64 kg)

LI6543XXX Models

54

542 gph (2052 lph)

310 gph (1174 lph)

142 lbs. (64 kg)

LI6573XXX Models

57

573 gph (2169 lph)

326 gph (1234 lph)

142 lbs. (64 kg)

NOTE: Storage capacity is 6 gallons (23 liters).

Form No. EBOOSTERBWM-1009

5

Page 7
Image 7
Bradford-White Corp MAGNUM Series Commercial Electric Booster Capacity, 40F 22C Rise 70F 39C Rise Shipping Weight, Model