Note: If the cable cannot be run inside the wall cavity, then the plastic knockout should be removed from the top or bottom of the control to allow flush mounting with the wall.
7.Disconnect the power from the water heater and remove the front cover.
8.Remove the plastic cover from the PCB and electrical connections.
9.Thread the cable through the access hole at the base of the water heater and connect the wires to the control terminals on the right hand side of the PCB.
REMOTE CONTROL
CONNECTION TERMINALS
REMOTE
CONTROL CABLE
CABLE CLAMP
Figure 38. Illustration Showing Where to Connect Remote Control Harness.
10.Secure the control cable using the clamp provided in the control compartment.
11.Replace the plastic cover over the PCB terminals and then replace the front control panel of the water heater.
WARNING
Do not attempt to connect the remote controls with the power on to the water heater. There is 120 volt terminals and wiring next to the remote control connections inside the unit. All servicing and wiring must be performed by a qualified installer.
WARNING
When the water heater or remotely located remote control is used in public use applications, it shall be installed in a location where it cannot be adjusted by the public (i.e. a maintenance room or manager’s office). Unauthorized adjustments may result in scalding conditions.
52