State Regulations

NOTICE BEFORE INSTALLATION

Bradford White direct-vent appliance must be installed by a state qualified or licensed contractor. If you are not properly trained, you must not install this unit.

IMPORTANT: In the State of Massachusetts (248CMR 4.00 & 5.00)

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of venting, including but not limited to decks and porches, the following requirements must be satisfied:

1.INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter must observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter must observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors. It is the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.

a.In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b.In the event that the requirements of this subdivision cannot be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm must be installed.

2.APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

3.SIGNAGE. A metal or plastic identification plate must be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign

must read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.

INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5308(2)(a)1 through 4.

12

Page 12
Image 12
Bradford-White Corp TGHE-199E-N(X), TGHE-160E-N(X) State Regulations, Important In the State of Massachusetts 248CMR 4.00

TGHE-160E-N(X), TGHE-199E-N(X) specifications

Bradford-White Corporation is renowned for its commitment to quality and innovation in the water heating industry. Among its extensive range of products, the TGHE-199E-N(X) and TGHE-160E-N(X) models stand out for their advanced technology and reliable performance, making them a preferred choice for both residential and commercial applications.

The TGHE-199E-N(X) and TGHE-160E-N(X) are high-efficiency, gas-fired water heaters designed to meet the rising demand for sustainable energy solutions without compromising on performance. Both models feature a powerful, energy-efficient design that significantly reduces energy consumption while providing a consistent supply of hot water.

One of the main features of these models is their use of advanced technology in water heating. The units are equipped with a high-efficiency burner and an optimized heat exchanger that maximizes the transfer of energy, ensuring rapid heating and minimal standby loss. This efficiency is further enhanced by their ability to modulate gas flow, allowing the heater to adjust its operation based on actual demand, rather than running at full capacity at all times.

Safety is a priority in the design of the TGHE-199E-N(X) and TGHE-160E-N(X). Both models are equipped with an electronic ignition system, which eliminates the need for a continuous pilot light, reducing gas consumption and enhancing safety. Furthermore, they include advanced venting options, such as concentric or PVC venting, providing installation flexibility while adhering to stringent building codes.

Moreover, these water heaters are built to last, featuring a durable tank design with a powder-coated, steel construction and a patented Vitraglas® lining. This lining protects against corrosion and extends the life of the tank, ensuring long-term performance and reliability.

Installation and maintenance of the TGHE-199E-N(X) and TGHE-160E-N(X) are straightforward, thanks to their user-friendly design. They come with easily accessible components, making service and repairs less time-consuming and more cost-effective.

In summary, the Bradford-White TGHE-199E-N(X) and TGHE-160E-N(X) gas-fired water heaters exemplify the best in modern water heating technology. Their energy efficiency, safety features, and durable construction make them a top choice for those seeking dependable hot water solutions in residential and commercial settings. With a commitment to innovation and quality, Bradford-White continues to lead the way in delivering superior water heating products.