Step 8: Electrical and supply connections
NOTE: Refer to Figure 6a below for
WARNING: | The Adaptive® Infrared control must be connected with a 24 VAC |
| Class II transformer. Connections to 110 VAC will result in damage to |
| the electronics and can cause personal injury. |
CAUTION: | Connection of leads other than shown may cause permanent damage |
| to the sensor. |
NOTE: Compliance and conformity to local codes and ordinance is the responsibility of the installer.
NOTE: The solenoid valves have been
1.Snap the senser circuit plug from the bowl into the solenoid circuit plug located on the valve bracket.
2.Snap the transformer circuit plug into the female transformer circuit plug located on the valve bracket.
3.Turn on the water supply to the Express® Crescent® Lavatory System and check for leaks.
4.Plug in the transformer and wait at least two minutes to allow the sensor to adapt to the environment.
5.Pass your hand in front of each station’s sensor until all the air is purged from the lines and water is flowing smoothly.
NOTE: The Vernatherm mixing valve is NOT factory preset. Upon installation, the temperature of this valve must be checked and adjusted to ensure delivery of a safe water temperature. Water in excess of 110°F (43°C) may cause scalding.