Step 8: Electrical and supply connections

 

Express® Crescent® Lavatory System - CRS-Series

Installation Instructions

CRS-2/IR, CRS-3/IR

 

 

Installation Instructions continued . . .

Step 8: Electrical and supply connections

NOTE: Refer to Figure 6a below for CRS-2/IR or Figure 6b on page 8 for CRS-3/IR.

WARNING:

The Adaptive® Infrared control must be connected with a 24 VAC

 

Class II transformer. Connections to 110 VAC will result in damage to

 

the electronics and can cause personal injury.

CAUTION:

Connection of leads other than shown may cause permanent damage

 

to the sensor.

NOTE: Compliance and conformity to local codes and ordinance is the responsibility of the installer.

NOTE: The solenoid valves have been pre-wired.

1.Snap the senser circuit plug from the bowl into the solenoid circuit plug located on the valve bracket.

2.Snap the transformer circuit plug into the female transformer circuit plug located on the valve bracket.

3.Turn on the water supply to the Express® Crescent® Lavatory System and check for leaks.

4.Plug in the transformer and wait at least two minutes to allow the sensor to adapt to the environment.

5.Pass your hand in front of each station’s sensor until all the air is purged from the lines and water is flowing smoothly.

NOTE: The Vernatherm mixing valve is NOT factory preset. Upon installation, the temperature of this valve must be checked and adjusted to ensure delivery of a safe water temperature. Water in excess of 110°F (43°C) may cause scalding.

GREEN SUPPLY TUBE

RED SUPPLY TUBE

 

(FROM SPRAYHEAD)

 

SENSOR CIRCUIT PLUG

(FROM SPRAYHEAD)

 

 

 

 

COMPRESSION NUT

 

 

(110-231)

 

TRANSFORMER

 

 

CIRCUIT PLUG

 

 

 

RED SPADE TERMINAL

 

 

WHITE SPADE TERMINAL

 

Figure 6a

GREEN SPADE TERMINAL

 

 

 

Bradley Corporation • 215-1330 Rev. K; EN 06-915

2/8/07

7