Bradley Smoker CRS-3/IR, CRS-2/IR installation instructions Connecting Supply, Install drain spud

Models: CRS-2/IR CRS-3/IR

1 14
Download 14 pages 31.38 Kb
Page 6
Image 6
Step 6: Install drain spud

Express® Crescent® Lavatory System - CRS-Series

 

CRS-2/IR, CRS-3/IR

Installation Instructions

Installation Instructions continued . . .

Step 6: Install drain spud

1.Assemble the P-trap by (supplied by installer) connecting the 1-1/2" tubular pipe to the 1-1/4" tailpiece and to the 1-1/2" drain pipe stubbed out of the wall (see Figure 4).

Step 7: Connecting Supply

1.Connect the 1/2" NPT female end of the stop/check valves to the rough-ins.

2.Connect one end of the supply hoses to the stop/check valves.

Step 7: Connecting SupplyManual background IMPORTANT: The hose attached to the hot Manual backgroundwater inlet of the Vernatherm™ TMV valve must be connected to the hot water rough-in.

DRAIN ASSEMBLY

STRAINER

1/4" RUBBER

AND

WASHER

TAILPIECE

 

269-1584

FIBER

 

 

WASHER

 

NUT

 

TRIM TO FIT

P-TRAP

 

(polypropylene)

Figure 4

269-1697

3.Connect the other end of the supply hoses to the Vernatherm™ TMV valve assembly.

4.OPTIONAL SINGLE-TEMPERED SUPPLY: Attach the stop/check valve to the 1/2" tempered supply line. Connect the stop/check valve to the solenoid valve with the flexible supply hose.

NOTE: The thermostatic mixing valve requires at least 115° F water from the hot water side for proper operation. As with all lavatories, there will be a delay in obtaining warm water. If the hot water is too far away from the washfountain, a circulating pump may be required.

 

VERNATHERM™

 

 

 

MIXING VALVE

 

 

 

COLD SUPPLY INLET

 

 

 

 

HOT

COLD

 

 

SUPPLY

 

 

SUPPLY

 

VALVE

 

STOP/CHECK

 

MOUNTING

 

 

 

VALVE

 

BRACKET

 

 

 

 

 

VERNATHERM™

 

 

 

MIXING VALVE

 

 

 

HOT SUPPLY INLET

 

FLEXIBLE

 

 

 

 

 

 

SUPPLY HOSE

 

Figure 5

 

 

6

2/8/07

Bradley Corporation • 215-1330 Rev. K; EN 06-915

Page 6
Image 6
Bradley Smoker CRS-3/IR, CRS-2/IR Connecting Supply, Install drain spud, Installation Instructions continued