![](/images/new-backgrounds/1063725/6372533x1.webp)
| Terreon® 54" |
Installation Instructions | TDB3104, WF3204 |
|
|
Installation Instructions continued . . .
NOTE: Flush supply lines before making connections.
4.Follow the procedures below and refer to Figure 12 when installing tubing to ensure that you achieve a leakproof seal. Install 3/8" supply tubing in the sprayhead using the male tube con- nector.
•Using a sharp razor, cut tubing squarely and remove any burrs. DO NOT pinch or crush end of tubing.
•Loosen nut on fitting. Moisten end of tube and push into fitting until it is firmly seated. Tighten nut to secure tube to fitting (make sure nut is securely tightened).
•If connector leaks, reseat tubing according to above procedure. If leaking persists, replace male connector, or call your Bradley representative for assistance.
SPRAYHEAD
MALE
TUBE
CONNECTOR
NUT
TUBING
TUBING
Figure 12
Bradley Corporation • | 2/8/07 | 17 |