product introduction

External I/O Pins

SSA-S30XX has 4 input pins and 4 output pins installed(2 relay and 2 TTL outputs) The input pins can receive signals from the Exit button and the Door Contact sensor, while the two relays can be connected to the Door Lock and the alarm device. You can specify the output time for these output pins. (Refer to “I/O Wiring” on pages 17 to 18)

Holiday Scheduling

In total, 10 holiday schedule codes are available for SSA-S30XX models, and each holiday schedule code can be confi gured for up to 100 holidays except Sundays. Each holiday code can be linked to the time schedule code.

You can set all holidays to holiday schedule codes, and holiday schedule code is based on the holiday time zone for the time scheduling. (Refer to “Holiday Scheduling” on page 56)

Forced Door Open Alarm

You can set the Forced Door Open Alarm to activate when the door is opened by force.

For its application, you must have installed the door contact sensor and properly set the door contact time and output settings for the alarm device. The Forced Door Open Alarm lasts until the alarm event is terminated. (Refer to “Door Contact Sensor” on page 44)

ANTIPASSBACK

A door has two card readers installed: one for the entrance, and the other for the exit, so anyone who enters should recognize his/her card on the reader at the entrance time before he can exit normally. If a person does not go under the card recognition process and just follows another person’s way inside the door, the person is not allowed to exit when he/she recognizes the access card on exit card reader, and the antipassback error (APB error) occurs which will be saved into the internal memory. And you can configure to output a signal through a specific pin when such an error occurs. (Refer to “Antipassback Error Output Setup” at pages 50 and 53.)

Arm/Disarm

As long as the device is in Arm mode, the reader ports are all frozen so that no one can get access to the door and any input from the corresponding external pin will not be processed. In this mode, SSA-S30XX transmits a specific signal to the connected security devices so that they responds properly. (Refer to “Arm/Disarm” on page 41)

Door Open Timeout Alarm

The Door Open Timeout Alarm notifies the administrator of the fact with an alarm if a door stays open after the normal service time. The Door Open Timeout Alarm lasts until the door is closed.

(Refer to “Door Open Timeout Setup” on page 48)

Duress Alarm

This is used in a situation where you should open the door inevitably by a robber insisting to do so. Entering the two- digit duress alarm password with pressing the ENT button and recognizing the registered card (or card number) opens the door, while this forcibly unarmed situation will be notified to the PC application with an alarm event. (Refer to “Duress Mode” on page 40)

Two Men Operation Mode

In this mode, SSA-S30XX permits a certain person (visitor) to enter or exit only when accompanied by a special user (administrator). Both the visitor and the administrator should be authorized before they can get access. (Refer to “Registering the ID card” on page 35)

4 Levels of Individual Door Opening Time Setting

You can use this function to set 4 different door opening time points. (Refer to “Output Setup for Level IDs Accessing Reader” at pages 48 and 51.)

Name Display

SSA-S30XX can display the name of a person when the person is authorized to get access. (Refer to “Name Display” on page 26)

8_ product introduction

Page 8
Image 8
Samsung SSA-S3010/EXP External I/O Pins, Holiday Scheduling, Forced Door Open Alarm, Arm/Disarm, Door Open Timeout Alarm