I/O time setup
EXIT BUTTON OUTPUT
1.Press the F5 SETUP MENU button.
2. Use the buttons 4 and 6 to move to the EXIT BUTTON item and press ENT .
3.You can make input when the prompt blinks.
•Use the keypad to enter the time for each output operation and press ENT . DR : Door relay output
AR : Alarm relay output
T1 : TTL #1 output
T2 : TTL #2 output
BZ : Buzzer output
1.EXIT BUTTON |
| |||
D R | A R | T 1 | T 2 | B Z |
0 3 | 0 0 | 0 0 | 0 0 | 0 0 |
1.EXIT BUTTON |
| |||
D R | A R | T 1 | T 2 | B Z |
_ 0 | 0 0 | 0 0 | 0 0 | 0 0 |
M | The output time differs, depending on the time unit. |
| If the time unit is 0.1 (second), you can specify the value between 0.0 and 9.8 second; if set to 1 (second), you can |
| specify between 0 and 98 seconds. |
| For the time unit, refer to the ‘Time Unit Setup’ under the advanced setup. (see page 54) |
| If you enter 99 for the value, the product stays in output mode until you change the setting regardless of the time |
| unit. |
DOOR CONTACT SENSOR SETUP
You can specify the signal output if a door is forcibly opened without through the normal authentication process. (The Door Contact sensor should have been installed.)
1.Press the F5 SETUP MENU button.
2. | Use the buttons 4 and 6 | to move to the DOOR CONTACT item and | 2.DOOR CONTACT |
| ||||
| press ENT . |
|
| |||||
3. | You can make input when the prompt blinks. | D R | A R | T 1 | T 2 | B Z | ||
0 0 | 9 9 | 0 0 | 0 0 | 0 0 | ||||
|
|
|
•Use the keypad to enter the time for each output operation and press ENT .
DR : Door relay output
AR : Alarm relay output | 2.DOOR CONTACT |
| ||||
|
|
|
|
| ||
T1 : TTL #1 output | D R | A R | T 1 | T 2 | B Z | |
T2 : TTL #2 output | ||||||
_ 0 | 9 9 | 0 0 | 0 0 | 0 0 | ||
BZ : Buzzer output |
|
|
|
|
| |
M The output time differs, depending on the time unit. |
|
|
|
|
|
If the time unit is 0.1 (second), you can specify the value between 0.0 and 9.8 second; if set to 1 (second), you can specify between 0 and 98 seconds.
For the time unit, refer to the ‘Time Unit Setup’ under the advanced setup. (see page 54)
If you enter 99 for the value, the product stays in output mode until you change the setting regardless of the time unit.
44_ I/O time setup