I/O time setup

TAMPER ALARM OUTPUT SETUP

You can set the signal that you want to output if the device is dismantled forcibly.

1.Press the F5 SETUP MENU button.

2. Use the buttons 4 and 6 to move to the TAMPER ALARM item and press ENT .

3.You can make input when the prompt blinks.

Use the keypad to enter the time for each output operation and press ENT . DR : Door relay output

AR : Alarm relay output

T1 : TTL #1 output

T2 : TTL #2 output

BZ : Buzzer output

5.TAMPER ALARM

D R

A R

T 1

T 2

B Z

0 0

9 9

9 9

9 9

9 9

5.TAMPER ALARM

 

D R

A R

T 1

T 2

B Z

_ 0

9 9

9 9

9 9

9 9

M

The output time differs, depending on the time unit.

 

If the time unit is 0.1 (second), you can specify the value between 0.0 and 9.8 second; if set to 1 (second), you can

 

specify between 0 and 98 seconds.

 

For the time unit, refer to the ‘Time Unit Setup’ under the advanced setup. (see page 54)

 

If you enter 99 for the value, the product stays in output mode until you change the setting regardless of the time

 

unit.

CUT OFF OUTPUT SETUP

You can set the output options when any of the input line is cut off.

The input cutoff check should have been activated. (see page 60)

1.Press the F5 SETUP MENU button.

2. Use the buttons 4 and 6 to move to the CUT OFF ALARM item and press ENT .

3.You can make input when the prompt blinks.

Use the keypad to enter the time for each output operation and press ENT . DR : Door relay output

AR : Alarm relay output

T1 : TTL #1 output

T2 : TTL #2 output

BZ : Buzzer output

6.CUT OFF ALARM

D R

A R

T 1

T 2

B Z

0 0

0 0

0 0

0 0

0 0

6.CUT OFF ALARM

 

D R

A R

T 1

T 2

B Z

_ 0

0 0

0 0

0 0

0 0

M

The output time differs, depending on the time unit.

 

If the time unit is 0.1 (second), you can specify the value between 0.0 and 9.8 second; if set to 1 (second), you can

 

specify between 0 and 98 seconds.

 

For the time unit, refer to the ‘Time Unit Setup’ under the advanced setup. (see page 54)

 

If you enter 99 for the value, the product stays in output mode until you change the setting regardless of the time

 

unit.

46_ I/O time setup

Page 46
Image 46
Samsung SSA-S3010/EXP manual Tamper Alarm Output Setup, CUT OFF Output Setup, CUT OFF Alarm