advanced setup

INPUT TIME SCHEDULE SETUP

You can assign a Time Schedule Code to each input to activate the input only during that period. The default Time Schedule Code for every input is “00”, which means no Time Schedule is applied to them. Changing these settings can be very useful when you want to activate PIR sensor during a certain period of time.

1.Press the F5 SETUP MENU button.

2. Use the buttons 4 and 6 to move to INPUT T/S and press ENT .

3.Use the numeric buttons to enter 2-digit code and press ENT .

T/S(Time Schedule) CODE : 00~10

EX : EXIT Button Input T/S Code

DC : Door Contact Sensor Input T/S Code

I1 : Aux Input#1 T/S Code

I2 : Aux Input#2 T/S Code

TP : Tamper Switch Input T/S Code

If the entry is incorrect, the “INVALID NUMBER” message will appear.

The T/S Code ‘00’ means no Time Schedules are to be applied.

11. INPUT

T/S

 

E X

D C

 

I 1

I 2

T P

0 0

0 0

0 0

0 0

0 0

11. INPUT

T/S

 

E X

D C

 

I 1

I 2

T P

1 0

0 0

0 2

0 0

0 0

INPUT CUT OFF CHECK SETUP

You can choose whether or not to check the connection cutoff of each input port. The default setting is “00”. To enable the cut off check function, change the setting to “01”.

In case of cut off detected at the input while the cut off check enabled, the corresponding output signal is given as per “Cut Off Output Setup”. (See Page 46.)

1.Press the F5 SETUP MENU button.

2. Use the buttons 4 and 6 to move to CUT OFF SET and press ENT .

3.Use the numeric buttons to enter “00” or “01” for each input.

00 : The Input Cut Off check function is disabled.

01 : The Input Cut Off check function is enabled.

EX : Whether to use EXIT Button input cut off check.

DC : Whether to use Door Contact Sensor input cut off check.

I1 : Whether to use Aux Input #1 input cut off check.

I2 : Whether to use Aux Input #2 input cut off check.

TP : Whether to use Tamper Switch input cut off check.

If the entry is incorrect, the “INVALID NUMBER” message will appear.

12. CUT OFF SET

E X

D C

I 1

I 2

T P

0 0

0 0

0 0

0 0

0 0

12.CUT OFF SET

 

E X

D C

I 1

I 2

T P

0 1

0 0

0 0

0 0

0 0

MBefore enabling this function, a 2.2KΩ resistor should be connected between the input wire and the GND.

60_ advanced setup

Page 60
Image 60
Samsung SSA-S3010/EXP manual Input Time Schedule Setup, Input CUT OFF Check Setup, Cut Off Set