EXTERNAL READER CONNECTION
External Reader Connection
183
%003
Mon 12 / 12 / 2009
10 : 30 : 20
1 2 3 F1 F2 F3
4 5 6 F4 F5 F6
7 8 9 F7 F8 F9
ESC 0 ENT F10 F11 F12
GND
Black -
Red +
DC+12V
Wiegand DATA0 (Pink)
Wiegand DATA1 (sky blue)
INSTALLATION AND EXTERNAL CONNECTION
Power
Supply
- Proximity Reader Connection
1.Connect the DC 12V(+) line of the power supply unit to the plus (+) line of the reader.
2.Connect the
3.Connect the Wiegand data input line 0 of the proximity reader to the pink line
4.Connect the Wiegand data input line 1 of the proximity reader to the sky blue line
•For a list of compliant readers (external readers), see the followings:
-Standard 26bit Wiegand format proximity reader
-Standard 26bit Wiegand + 8bit Burst format proximity/keypad reader
-Standard 34bit Wiegand format proximity reader
-Standard 34bit Wiegand + 8bit Burst format proximity/keypad reader
English _ 19