EXTERNAL READER CONNECTION

External Reader Connection

183

"-.

%003

Mon 12 / 12 / 2009

10 : 30 : 20

1 2 3 F1 F2 F3

4 5 6 F4 F5 F6

7 8 9 F7 F8 F9

ESC 0 ENT F10 F11 F12

GND

Black -

Red +

DC+12V

Wiegand DATA0 (Pink)

Wiegand DATA1 (sky blue)

INSTALLATION AND EXTERNAL CONNECTION

Power

Supply

- Proximity Reader Connection

1.Connect the DC 12V(+) line of the power supply unit to the plus (+) line of the reader.

2.Connect the GND(-) line of the power supply unit to the minus(-) line of the reader

3.Connect the Wiegand data input line 0 of the proximity reader to the pink line

4.Connect the Wiegand data input line 1 of the proximity reader to the sky blue line

For a list of compliant readers (external readers), see the followings: SSA-S30X0

-Standard 26bit Wiegand format proximity reader

-Standard 26bit Wiegand + 8bit Burst format proximity/keypad reader SSA-S30X1

-Standard 34bit Wiegand format proximity reader

-Standard 34bit Wiegand + 8bit Burst format proximity/keypad reader

English _ 19

Page 19
Image 19
Samsung SSA-S3010/EXP manual External Reader Connection